{"id":552,"date":"2024-03-14T00:40:24","date_gmt":"2024-03-14T00:40:24","guid":{"rendered":"https:\/\/vnit.ac.in\/engineering\/electrical\/dr-mrs-m-a-chaudhari-copy\/"},"modified":"2026-01-19T06:21:11","modified_gmt":"2026-01-19T06:21:11","slug":"dr-m-s-ballal","status":"publish","type":"page","link":"https:\/\/vnit.ac.in\/engineering\/electrical\/dr-m-s-ballal\/","title":{"rendered":"Dr. M. S. Ballal"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"552\" class=\"elementor elementor-552\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4a74b67 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4a74b67\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cf7c068\" data-id=\"cf7c068\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-981f5f0 elementor-widget elementor-widget-heading\" data-id=\"981f5f0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Dr. M. S. Ballal<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-39d0a8b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"39d0a8b\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-7355120\" data-id=\"7355120\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ef27958 elementor-widget elementor-widget-heading\" data-id=\"ef27958\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Brief Bio<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-435e886 elementor-widget elementor-widget-text-editor\" data-id=\"435e886\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div id=\"footable_parent_1877\"\n         class=\" footable_parent ninja_table_wrapper loading_ninja_table wp_table_data_press_parent semantic_ui \">\n                <table data-ninja_table_instance=\"ninja_table_instance_0\" data-footable_id=\"1877\" data-filter-delay=\"1000\" aria-label=\"Bio_MSB\"            id=\"footable_1877\"\n           data-unique_identifier=\"ninja_table_unique_id_353842122_1877\"\n           class=\" foo-table ninja_footable foo_table_1877 ninja_table_unique_id_353842122_1877 ui table  nt_type_legacy_table selectable striped vertical_centered  footable-paging-right ninja_table_pro\">\n                <colgroup>\n                            <col class=\"ninja_column_0 \">\n                            <col class=\"ninja_column_1 \">\n                    <\/colgroup>\n        <thead>\n<tr class=\"footable-header\">\n                                        <th scope=\"col\"  class=\"ninja_column_0 ninja_clmn_nm_briefbio \">Brief Bio<\/th><th scope=\"col\"  class=\"ninja_column_1 ninja_clmn_nm_count \">Count<\/th><\/tr>\n<\/thead>\n<tbody>\n\n        <tr data-row_id=\"0\" class=\"ninja_table_row_0 nt_row_id_0\">\n            <td>Patent Granted<\/td><td>24<\/td>        <\/tr>\n            <tr data-row_id=\"1\" class=\"ninja_table_row_1 nt_row_id_1\">\n            <td>National Patent Granted<\/td><td>16<\/td>        <\/tr>\n            <tr data-row_id=\"2\" class=\"ninja_table_row_2 nt_row_id_2\">\n            <td>International Patent Granted<\/td><td>7<\/td>        <\/tr>\n            <tr data-row_id=\"3\" class=\"ninja_table_row_3 nt_row_id_3\">\n            <td>National Patent Filed<\/td><td>6<\/td>        <\/tr>\n            <tr data-row_id=\"4\" class=\"ninja_table_row_4 nt_row_id_4\">\n            <td>Technology Transfer<\/td><td>6<\/td>        <\/tr>\n            <tr data-row_id=\"5\" class=\"ninja_table_row_5 nt_row_id_5\">\n            <td>Research Project  Completed<\/td><td>6<\/td>        <\/tr>\n            <tr data-row_id=\"6\" class=\"ninja_table_row_6 nt_row_id_6\">\n            <td>Research Project  Ongoing<\/td><td>1<\/td>        <\/tr>\n            <tr data-row_id=\"7\" class=\"ninja_table_row_7 nt_row_id_7\">\n            <td>Consultancy Projects  <\/td><td>12<\/td>        <\/tr>\n            <tr data-row_id=\"8\" class=\"ninja_table_row_8 nt_row_id_8\">\n            <td>Papers Published in IEEE<\/td><td>28<\/td>        <\/tr>\n            <tr data-row_id=\"9\" class=\"ninja_table_row_9 nt_row_id_9\">\n            <td>Papers Published in IET<\/td><td>8<\/td>        <\/tr>\n            <tr data-row_id=\"10\" class=\"ninja_table_row_10 nt_row_id_10\">\n            <td>Papers Published in SCI \/ SCOPUS\/REPUTE Journals<\/td><td>58<\/td>        <\/tr>\n            <tr data-row_id=\"11\" class=\"ninja_table_row_11 nt_row_id_11\">\n            <td>Papers Published in Journal<\/td><td>94<\/td>        <\/tr>\n            <tr data-row_id=\"12\" class=\"ninja_table_row_12 nt_row_id_12\">\n            <td>Papers Published in Conferences<\/td><td>97<\/td>        <\/tr>\n            <tr data-row_id=\"13\" class=\"ninja_table_row_13 nt_row_id_13\">\n            <td>Power Sector Experience<\/td><td>15 Years<\/td>        <\/tr>\n            <tr data-row_id=\"14\" class=\"ninja_table_row_14 nt_row_id_14\">\n            <td>Awards<\/td><td>4<\/td>        <\/tr>\n            <tr data-row_id=\"15\" class=\"ninja_table_row_15 nt_row_id_15\">\n            <td>Ph D Outcome<\/td><td>12<\/td>        <\/tr>\n    <\/tbody><!--ninja_tobody_rendering_done-->\n    <\/table>\n    \n    \n    \n<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-12cff82 elementor-widget elementor-widget-heading\" data-id=\"12cff82\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Education<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2b75072 elementor-widget elementor-widget-text-editor\" data-id=\"2b75072\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div id=\"footable_parent_557\"\n         class=\" footable_parent ninja_table_wrapper loading_ninja_table wp_table_data_press_parent semantic_ui \">\n                <table data-ninja_table_instance=\"ninja_table_instance_1\" data-footable_id=\"557\" data-filter-delay=\"1000\" aria-label=\"73\"            id=\"footable_557\"\n           data-unique_identifier=\"ninja_table_unique_id_4262613509_557\"\n           class=\" foo-table ninja_footable foo_table_557 ninja_table_unique_id_4262613509_557 ui table  nt_type_legacy_table selectable striped vertical_centered  footable-paging-right ninja_table_search_disabled ninja_table_pro\">\n                <colgroup>\n                            <col class=\"ninja_column_0 \">\n                            <col class=\"ninja_column_1 \">\n                            <col class=\"ninja_column_2 \">\n                            <col class=\"ninja_column_3 \">\n                            <col class=\"ninja_column_4 \">\n                    <\/colgroup>\n        <thead>\n<tr class=\"footable-header\">\n                                                                                        <th scope=\"col\"  class=\"ninja_column_0 ninja_clmn_nm_srno \">Sr. No.<\/th><th scope=\"col\"  class=\"ninja_column_1 ninja_clmn_nm_degree \">Degree<\/th><th scope=\"col\"  class=\"ninja_column_2 ninja_clmn_nm_year \">Year<\/th><th scope=\"col\"  class=\"ninja_column_3 ninja_clmn_nm_specialization \">Specialization<\/th><th scope=\"col\"  class=\"ninja_column_4 ninja_clmn_nm_university \">University<\/th><\/tr>\n<\/thead>\n<tbody>\n\n        <tr data-row_id=\"0\" class=\"ninja_table_row_0 nt_row_id_0\">\n            <td>1<\/td><td>Ph D <\/td><td>2007<\/td><td>Condition Monitoring of Electrical Machines<\/td><td>RTM Nagpur University, Nagpur<\/td>        <\/tr>\n            <tr data-row_id=\"1\" class=\"ninja_table_row_1 nt_row_id_1\">\n            <td>2<\/td><td>M Tech (IPS)<\/td><td>1997<\/td><td>Induction Motor Fault Detection by ANN and Fuzzy Systems<\/td><td>VNIT Nagpur ( Formerley VRCE Nagpur)<\/td>        <\/tr>\n            <tr data-row_id=\"2\" class=\"ninja_table_row_2 nt_row_id_2\">\n            <td>3<\/td><td>B E<\/td><td>1993<\/td><td>Electrical Engineering<\/td><td>Govt. Engineering Collage, Aurangabad (MS)<\/td>        <\/tr>\n            <tr data-row_id=\"3\" class=\"ninja_table_row_3 nt_row_id_3\">\n            <td>4<\/td><td>Diploma<\/td><td>1990<\/td><td>Electrical Engineering<\/td><td>Govt. Polytechnic, Yavatmal (MS)<\/td>        <\/tr>\n    <\/tbody><!--ninja_tobody_rendering_done-->\n    <\/table>\n    \n    \n    \n<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e01ab5e elementor-widget elementor-widget-heading\" data-id=\"e01ab5e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Contact Details\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55db774 elementor-widget elementor-widget-text-editor\" data-id=\"55db774\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div id=\"footable_parent_1938\"\n         class=\" footable_parent ninja_table_wrapper loading_ninja_table wp_table_data_press_parent semantic_ui \">\n                <table data-ninja_table_instance=\"ninja_table_instance_2\" data-footable_id=\"1938\" data-filter-delay=\"1000\" aria-label=\"Contact_MSB\"            id=\"footable_1938\"\n           data-unique_identifier=\"ninja_table_unique_id_4089888450_1938\"\n           class=\" foo-table ninja_footable foo_table_1938 ninja_table_unique_id_4089888450_1938 ui table  nt_type_legacy_table selectable striped vertical_centered  footable-paging-right ninja_table_pro\">\n                <colgroup>\n                            <col class=\"ninja_column_0 \">\n                            <col class=\"ninja_column_1 \">\n                            <col class=\"ninja_column_2 \">\n                    <\/colgroup>\n        <thead>\n<tr class=\"footable-header\">\n                                                        <th scope=\"col\"  class=\"ninja_column_0 ninja_clmn_nm_phone \">Phone:<\/th><th scope=\"col\"  class=\"ninja_column_1 ninja_clmn_nm_email \">Email:<\/th><th scope=\"col\"  class=\"ninja_column_2 ninja_clmn_nm_address \">Address:<\/th><\/tr>\n<\/thead>\n<tbody>\n\n        <tr data-row_id=\"0\" class=\"ninja_table_row_0 nt_row_id_0\">\n            <td>7122801147<\/td><td>msballal@eee.vnit.ac.in<\/td><td>EED, VNIT, NGP<\/td>        <\/tr>\n    <\/tbody><!--ninja_tobody_rendering_done-->\n    <\/table>\n    \n    \n    \n<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-8677599\" data-id=\"8677599\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-482e49a elementor-widget elementor-widget-image\" data-id=\"482e49a\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/vnit.ac.in\/engineering\/electrical\/wp-content\/uploads\/2025\/05\/MSB.jpg\" class=\"attachment-full size-full wp-image-1942\" alt=\"\" srcset=\"https:\/\/vnit.ac.in\/engineering\/electrical\/wp-content\/uploads\/2025\/05\/MSB.jpg 1000w, https:\/\/vnit.ac.in\/engineering\/electrical\/wp-content\/uploads\/2025\/05\/elementor\/thumbs\/MSB-r57pkp6yzxr6wp3uqpgpgg93tyf9wt9glngvnj5pdk.jpg 300w, https:\/\/vnit.ac.in\/engineering\/electrical\/wp-content\/uploads\/2025\/05\/MSB-150x150.jpg 150w, https:\/\/vnit.ac.in\/engineering\/electrical\/wp-content\/uploads\/2025\/05\/MSB-768x768.jpg 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d917aa8 elementor-widget elementor-widget-heading\" data-id=\"d917aa8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Research Interest<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fe34061 elementor-widget elementor-widget-text-editor\" data-id=\"fe34061\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div id=\"footable_parent_556\"\n         class=\" footable_parent ninja_table_wrapper loading_ninja_table wp_table_data_press_parent semantic_ui \">\n                <table data-ninja_table_instance=\"ninja_table_instance_3\" data-footable_id=\"556\" data-filter-delay=\"1000\" aria-label=\"72\"            id=\"footable_556\"\n           data-unique_identifier=\"ninja_table_unique_id_2617130925_556\"\n           class=\" foo-table ninja_footable foo_table_556 ninja_table_unique_id_2617130925_556 ui table  nt_type_legacy_table selectable striped vertical_centered  footable-paging-right ninja_table_search_disabled ninja_table_pro\">\n                <colgroup>\n                            <col class=\"ninja_column_0 \">\n                    <\/colgroup>\n        <thead>\n<tr class=\"footable-header\">\n                        <th scope=\"col\"  class=\"ninja_column_0 ninja_clmn_nm_researchinterest \">Research Interest<\/th><\/tr>\n<\/thead>\n<tbody>\n\n        <tr data-row_id=\"0\" class=\"ninja_table_row_0 nt_row_id_0\">\n            <td>1.   Condition Monitoring of Electrical Components<\/td>        <\/tr>\n            <tr data-row_id=\"1\" class=\"ninja_table_row_1 nt_row_id_1\">\n            <td>2.   DC Microgrid Control and Protection<\/td>        <\/tr>\n            <tr data-row_id=\"2\" class=\"ninja_table_row_2 nt_row_id_2\">\n            <td>3.   Power Systems<\/td>        <\/tr>\n            <tr data-row_id=\"3\" class=\"ninja_table_row_3 nt_row_id_3\">\n            <td>4.   Power Quality<\/td>        <\/tr>\n            <tr data-row_id=\"4\" class=\"ninja_table_row_4 nt_row_id_4\">\n            <td>5.   Power Theft<\/td>        <\/tr>\n    <\/tbody><!--ninja_tobody_rendering_done-->\n    <\/table>\n    \n    \n    \n<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a073dcb elementor-shape-rounded elementor-grid-0 e-grid-align-center elementor-widget elementor-widget-social-icons\" data-id=\"a073dcb\" data-element_type=\"widget\" data-widget_type=\"social-icons.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-social-icons-wrapper elementor-grid\" role=\"list\">\n\t\t\t\t\t\t\t<span class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t<a class=\"elementor-icon elementor-social-icon elementor-social-icon-linkedin elementor-repeater-item-12041c6\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-screen-only\">Linkedin<\/span>\n\t\t\t\t\t\t<i class=\"fab fa-linkedin\"><\/i>\t\t\t\t\t<\/a>\n\t\t\t\t<\/span>\n\t\t\t\t\t\t\t<span class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t<a class=\"elementor-icon elementor-social-icon elementor-social-icon- elementor-repeater-item-74a646b\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-screen-only\"><\/span>\n\t\t\t\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" width=\"500\" viewBox=\"0 0 375 374.999991\" height=\"500\" preserveAspectRatio=\"xMidYMid meet\"><defs><g><\/g><\/defs><rect x=\"-37.5\" width=\"450\" fill=\"#ffffff\" y=\"-37.499999\" height=\"449.999989\" fill-opacity=\"1\"><\/rect><rect x=\"-37.5\" width=\"450\" fill=\"#ffffff\" y=\"-37.499999\" height=\"449.999989\" fill-opacity=\"1\"><\/rect><rect x=\"-37.5\" width=\"450\" fill=\"#01d0b0\" y=\"-37.499999\" height=\"449.999989\" fill-opacity=\"1\"><\/rect><g fill=\"#feffff\" fill-opacity=\"1\"><g transform=\"translate(30.712213, 343.991664)\"><g><path d=\"M 27.925781 0 L 27.925781 -232.304688 L 82.511719 -232.304688 C 98.0625 -232.304688 109.460938 -231.433594 116.707031 -229.6875 C 123.953125 -227.941406 130.328125 -224.953125 135.828125 -220.722656 C 142.707031 -215.328125 148.046875 -208.109375 151.855469 -199.0625 C 155.664062 -190.019531 157.570312 -179.996094 157.570312 -168.992188 C 157.570312 -149.953125 152.253906 -135.484375 141.621094 -125.59375 C 130.988281 -115.703125 115.414062 -110.757812 94.890625 -110.757812 L 89.972656 -110.757812 L 178.671875 0 L 143.605469 0 L 58.871094 -110.757812 L 54.902344 -110.757812 L 54.902344 0 Z M 54.902344 -208.980469 L 54.902344 -131.226562 L 76.007812 -131.226562 C 97.585938 -131.226562 112.027344 -134.003906 119.328125 -139.558594 C 126.625 -145.113281 130.277344 -154.816406 130.277344 -168.675781 C 130.277344 -183.59375 126.519531 -194.039062 119.007812 -200.015625 C 111.5 -205.992188 97.164062 -208.980469 76.007812 -208.980469 Z M 54.902344 -208.980469 \"><\/path><\/g><\/g><\/g><g fill=\"#feffff\" fill-opacity=\"1\"><g transform=\"translate(199.286607, 158.744914)\"><g><path d=\"M 75.945312 -58.527344 L 122.707031 -58.527344 L 122.707031 -54.734375 C 122.707031 -36.875 117.648438 -22.785156 107.53125 -12.464844 C 97.417969 -2.140625 83.609375 3.019531 66.113281 3.019531 C 60.796875 3.019531 55.726562 2.453125 50.902344 1.316406 C 46.074219 0.179688 41.625 -1.472656 37.546875 -3.636719 C 28.257812 -8.75 21.082031 -15.804688 16.023438 -24.8125 C 10.96875 -33.816406 8.4375 -44.050781 8.4375 -55.507812 C 8.4375 -64.953125 9.949219 -73.480469 12.96875 -81.09375 C 15.988281 -88.707031 20.542969 -95.402344 26.632812 -101.183594 C 31.742188 -106.035156 37.675781 -109.699219 44.4375 -112.175781 C 51.199219 -114.65625 58.683594 -115.894531 66.886719 -115.894531 C 77.777344 -115.894531 87.222656 -113.917969 95.222656 -109.972656 C 103.222656 -106.023438 109.855469 -100.074219 115.117188 -92.125 L 103.816406 -83.070312 C 99.738281 -89.933594 94.65625 -95.082031 88.566406 -98.511719 C 82.476562 -101.945312 75.402344 -103.660156 67.351562 -103.660156 C 54.191406 -103.660156 43.507812 -99.222656 35.300781 -90.34375 C 27.097656 -81.46875 22.992188 -69.855469 22.992188 -55.507812 C 22.992188 -41.984375 27.160156 -30.890625 35.496094 -22.21875 C 43.832031 -13.546875 54.449219 -9.210938 67.351562 -9.210938 C 78.707031 -9.210938 88.164062 -12.65625 95.726562 -19.546875 C 103.289062 -26.4375 107.480469 -35.40625 108.304688 -46.449219 L 75.945312 -46.449219 Z M 75.945312 -58.527344 \"><\/path><\/g><\/g><\/g><\/svg>\t\t\t\t\t<\/a>\n\t\t\t\t<\/span>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-42d250d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"42d250d\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-9861d74\" data-id=\"9861d74\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9eac3f5 elementor-widget-tablet__width-initial elementor-widget elementor-widget-eael-adv-tabs\" data-id=\"9eac3f5\" data-element_type=\"widget\" data-widget_type=\"eael-adv-tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div data-scroll-on-click=\"no\" data-scroll-speed=\"300\" id=\"eael-advance-tabs-9eac3f5\" class=\"eael-advance-tabs eael-tabs-horizontal eael-tab-auto-active \" data-tabid=\"9eac3f5\">\n            <div class=\"eael-tabs-nav \">\n                <ul class=\"\" role=\"tablist\">\n                                            <li id=\"sponsored-research-projects-\" class=\"active-default eael-tab-item-trigger eael-tab-nav-item\" aria-selected=\"true\" data-tab=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"sponsored-research-projects--tab\" aria-expanded=\"false\">\n                            \n                            \n                            \n                                                            <span class=\"eael-tab-title title-after-icon\" >Sponsored Research Projects\t<\/span>                                                    <\/li>\n                                            <li id=\"consultancy-projects\" class=\"inactive eael-tab-item-trigger eael-tab-nav-item\" aria-selected=\"false\" data-tab=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"consultancy-projects-tab\" aria-expanded=\"false\">\n                            \n                            \n                            \n                                                            <span class=\"eael-tab-title title-after-icon\" >Consultancy Projects<\/span>                                                    <\/li>\n                                            <li id=\"book-or-book-chapters\" class=\"inactive eael-tab-item-trigger eael-tab-nav-item\" aria-selected=\"false\" data-tab=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"book-or-book-chapters-tab\" aria-expanded=\"false\">\n                            \n                            \n                            \n                                                            <span class=\"eael-tab-title title-after-icon\" >Book or Book Chapters<\/span>                                                    <\/li>\n                                            <li id=\"patents\" class=\"inactive eael-tab-item-trigger eael-tab-nav-item\" aria-selected=\"false\" data-tab=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"patents-tab\" aria-expanded=\"false\">\n                            \n                            \n                            \n                                                            <span class=\"eael-tab-title title-after-icon\" >Patents<\/span>                                                    <\/li>\n                                            <li id=\"sttp-workshop\" class=\"inactive eael-tab-item-trigger eael-tab-nav-item\" aria-selected=\"false\" data-tab=\"5\" role=\"tab\" tabindex=\"-1\" aria-controls=\"sttp-workshop-tab\" aria-expanded=\"false\">\n                            \n                            \n                            \n                                                            <span class=\"eael-tab-title title-after-icon\" >STTP &#038; Workshop<\/span>                                                    <\/li>\n                                            <li id=\"administrative-responsibilities\" class=\"inactive eael-tab-item-trigger eael-tab-nav-item\" aria-selected=\"false\" data-tab=\"6\" role=\"tab\" tabindex=\"-1\" aria-controls=\"administrative-responsibilities-tab\" aria-expanded=\"false\">\n                            \n                            \n                            \n                                                            <span class=\"eael-tab-title title-after-icon\" >Administrative Responsibilities<\/span>                                                    <\/li>\n                                            <li id=\"awards-honors\" class=\"inactive eael-tab-item-trigger eael-tab-nav-item\" aria-selected=\"false\" data-tab=\"7\" role=\"tab\" tabindex=\"-1\" aria-controls=\"awards-honors-tab\" aria-expanded=\"false\">\n                            \n                            \n                            \n                                                            <span class=\"eael-tab-title title-after-icon\" >Awards &#038; Honors<\/span>                                                    <\/li>\n                                            <li id=\"journal-publications\" class=\"inactive eael-tab-item-trigger eael-tab-nav-item\" aria-selected=\"false\" data-tab=\"8\" role=\"tab\" tabindex=\"-1\" aria-controls=\"journal-publications-tab\" aria-expanded=\"false\">\n                            \n                            \n                            \n                                                            <span class=\"eael-tab-title title-after-icon\" >Journal Publications<\/span>                                                    <\/li>\n                                            <li id=\"conference-publications\" class=\"inactive eael-tab-item-trigger eael-tab-nav-item\" aria-selected=\"false\" data-tab=\"9\" role=\"tab\" tabindex=\"-1\" aria-controls=\"conference-publications-tab\" aria-expanded=\"false\">\n                            \n                            \n                            \n                                                            <span class=\"eael-tab-title title-after-icon\" >Conference Publications<\/span>                                                    <\/li>\n                    \n                                  <\/ul>\n            <\/div>\n            \n            <div class=\"eael-tabs-content\">\n\t\t        \n                    <div id=\"sponsored-research-projects--tab\" class=\"clearfix eael-tab-content-item active-default\" data-title-link=\"sponsored-research-projects--tab\">\n\t\t\t\t        <div id=\"footable_parent_1885\"\n         class=\" footable_parent ninja_table_wrapper loading_ninja_table wp_table_data_press_parent semantic_ui \">\n                <table data-ninja_table_instance=\"ninja_table_instance_0\" data-footable_id=\"1885\" data-filter-delay=\"1000\" aria-label=\"Proj_MSB\"            id=\"footable_1885\"\n           data-unique_identifier=\"ninja_table_unique_id_1089359581_1885\"\n           class=\" foo-table ninja_footable foo_table_1885 ninja_table_unique_id_1089359581_1885 ui table  nt_type_legacy_table selectable striped vertical_centered  footable-paging-right ninja_table_pro\">\n                <colgroup>\n                            <col class=\"ninja_column_0 \">\n                            <col class=\"ninja_column_1 \">\n                            <col class=\"ninja_column_2 \">\n                            <col class=\"ninja_column_3 \">\n                            <col class=\"ninja_column_4 \">\n                            <col class=\"ninja_column_5 \">\n                            <col class=\"ninja_column_6 \">\n                    <\/colgroup>\n        <thead>\n<tr class=\"footable-header\">\n                                                                                                                        <th scope=\"col\"  class=\"ninja_column_0 ninja_clmn_nm_srno \">Sr. No.<\/th><th scope=\"col\"  class=\"ninja_column_1 ninja_clmn_nm_titleofproject \">Title of Project<\/th><th scope=\"col\"  class=\"ninja_column_2 ninja_clmn_nm_period \">Period<\/th><th scope=\"col\"  class=\"ninja_column_3 ninja_clmn_nm_sponsoringorganisation \">Sponsoring Organisation<\/th><th scope=\"col\"  class=\"ninja_column_4 ninja_clmn_nm_amountinlakhs \">Amount (in lakhs)<\/th><th scope=\"col\"  class=\"ninja_column_5 ninja_clmn_nm_noofinvestigators \">No. of Investigator(s)<\/th><th scope=\"col\"  class=\"ninja_column_6 ninja_clmn_nm_picopi \">PI\/CoPI<\/th><\/tr>\n<\/thead>\n<tbody>\n\n        <tr data-row_id=\"0\" class=\"ninja_table_row_0 nt_row_id_0\">\n            <td>1<\/td><td>A Solution for Stable and Combined Operation of multiple Renewable Sources: Intelligent DC Microgrid(IMP\/2018\/000179)<\/td><td>15-01.2019 to 14.01.2022<\/td><td>DST-SERB IMPRINT-II<\/td><td>42.55<\/td><td>2<\/td><td>PI<\/td>        <\/tr>\n            <tr data-row_id=\"1\" class=\"ninja_table_row_1 nt_row_id_1\">\n            <td>2<\/td><td>Development of Efficient converter for Grid Integration<\/td><td>15.06.15 To14.06.18<\/td><td>DST Solar Oriented Fundamental Research (SOFR)<\/td><td>58<\/td><td>2<\/td><td>CoPI<\/td>        <\/tr>\n            <tr data-row_id=\"2\" class=\"ninja_table_row_2 nt_row_id_2\">\n            <td>3<\/td><td>Error Compensation Techniques in Industrial Metering<\/td><td>16.10.15 To 05.12.16<\/td><td>M\/s. Koyna engineers Pvt. Ltd., Nasik, Maharashtra, India.<\/td><td>1.74<\/td><td>2<\/td><td>PI<\/td>        <\/tr>\n            <tr data-row_id=\"3\" class=\"ninja_table_row_3 nt_row_id_3\">\n            <td>4<\/td><td>Development of Test-Bench for performing various Tests of Transformer<\/td><td>01.03.16 To 23.10.18<\/td><td>M\/s. High Rise Engineers Pvt. Ltd., Nagpur, Maharashtra, India.<\/td><td>10.04<\/td><td>2<\/td><td>PI<\/td>        <\/tr>\n            <tr data-row_id=\"4\" class=\"ninja_table_row_4 nt_row_id_4\">\n            <td>5<\/td><td>Design of Low cost EV Charging Station and its Condition Monitoring (Phase 1)<\/td><td>07-06-2022 To 06.06.2023<\/td><td>Arise Engineers Pvt Ltd. Vadaodara Gujarat<\/td><td>6<\/td><td>1<\/td><td>PI<\/td>        <\/tr>\n            <tr data-row_id=\"5\" class=\"ninja_table_row_5 nt_row_id_5\">\n            <td>6<\/td><td>Condition Monitoring and Protection of EV Battery Pack (Phase 2)<\/td><td>06-07-2023 on going<\/td><td>Arise Engineers Pvt Ltd. Vadaodara Gujarat<\/td><td>3.54<\/td><td>1<\/td><td>PI<\/td>        <\/tr>\n            <tr data-row_id=\"6\" class=\"ninja_table_row_6 nt_row_id_6\">\n            <td>7<\/td><td>A IoT based System Identification and Condition Monitoring of Islanded Smaert EV Charging Station<\/td><td>20.05.2024 ongoing<\/td><td>Inhouse R&amp;D Project, VNIT, Nagpur<\/td><td>15<\/td><td>3<\/td><td>CoPI<\/td>        <\/tr>\n            <tr data-row_id=\"7\" class=\"ninja_table_row_7 nt_row_id_7\">\n            <td><\/td><td>Technology Transfer<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"8\" class=\"ninja_table_row_8 nt_row_id_8\">\n            <td>SN<\/td><td>Year of Project\/ Consultancy<\/td><td>Name of Industry<\/td><td>Innovation Details<\/td><td>Date of Transfer<\/td><td><\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"9\" class=\"ninja_table_row_9 nt_row_id_9\">\n            <td>1<\/td><td>2022-2024<\/td><td>M\/s Arise Engineers Private Limited, Vadodara, Gujarat.<\/td><td>Determination of Lithium-ion Cells used in EV<\/td><td>Director office No 32 Date 05.09.2024<\/td><td><\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"10\" class=\"ninja_table_row_10 nt_row_id_10\">\n            <td>2<\/td><td>2022-2023<\/td><td>DST<\/td><td>DC Microgrid Control <\/td><td>11.03.2022<\/td><td><\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"11\" class=\"ninja_table_row_11 nt_row_id_11\">\n            <td>3<\/td><td>2022-2023<\/td><td>M\/s Arise Engineers Private Limited, Vadodara, Gujarat.<\/td><td>Solar Panel Analyzing and Reporting Kit (SPARK)<\/td><td>Director office No 08 Date 19.05.2023<\/td><td><\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"12\" class=\"ninja_table_row_12 nt_row_id_12\">\n            <td>4<\/td><td>2016-2018<\/td><td>M\/S High Rise Transformers Pvt. Ltd. Nagpur, 2018.<\/td><td>Development of Test Bench for performing various tests of Transformers<\/td><td>Director office No  &#8212;  Date 12.11.2018 and HRT\/NGP\/R&amp;D\/Proj\/2860 Date 23.12.2018<\/td><td><\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"13\" class=\"ninja_table_row_13 nt_row_id_13\">\n            <td>5<\/td><td>2015-2017<\/td><td>M\/s Koyana Engineers Pvt. Ltd, Nasik India, 2016<\/td><td>Error Compensation Techniques in Industrial Metering<\/td><td>Director office No &#8212; Date 09.12.2016<\/td><td><\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"14\" class=\"ninja_table_row_14 nt_row_id_14\">\n            <td>6<\/td><td>2015-2016<\/td><td>Tesla Transformer Ltd., Bhopal (MP), 2016.<\/td><td>Condition monitoring performance evaluation of the distribution\/power transformer health,<\/td><td>Director office No &#8211; 14 Date 08.02.2016 TTL\/02\/2016\/07 Date 22.02.2016<\/td><td><\/td><td><\/td>        <\/tr>\n    <\/tbody><!--ninja_tobody_rendering_done-->\n    <\/table>\n    \n    \n    \n<\/div>\n                    <\/div>\n\t\t        \n                    <div id=\"consultancy-projects-tab\" class=\"clearfix eael-tab-content-item inactive\" data-title-link=\"consultancy-projects-tab\">\n\t\t\t\t        <div id=\"footable_parent_560\"\n         class=\" footable_parent ninja_table_wrapper loading_ninja_table wp_table_data_press_parent semantic_ui \">\n                <table data-ninja_table_instance=\"ninja_table_instance_1\" data-footable_id=\"560\" data-filter-delay=\"1000\" aria-label=\"76\"            id=\"footable_560\"\n           data-unique_identifier=\"ninja_table_unique_id_1759102417_560\"\n           class=\" foo-table ninja_footable foo_table_560 ninja_table_unique_id_1759102417_560 ui table  nt_type_legacy_table selectable striped vertical_centered  footable-paging-right ninja_table_pro\">\n                <colgroup>\n                            <col class=\"ninja_column_0 \">\n                            <col class=\"ninja_column_1 \">\n                            <col class=\"ninja_column_2 \">\n                            <col class=\"ninja_column_3 \">\n                            <col class=\"ninja_column_4 \">\n                            <col class=\"ninja_column_5 \">\n                    <\/colgroup>\n        <thead>\n<tr class=\"footable-header\">\n                                                                                                        <th scope=\"col\"  class=\"ninja_column_0 ninja_clmn_nm_srno \">Sr. No.<\/th><th scope=\"col\"  class=\"ninja_column_1 ninja_clmn_nm_title \">Title<\/th><th scope=\"col\"  class=\"ninja_column_2 ninja_clmn_nm_fundingagency \">Funding Agency<\/th><th scope=\"col\"  class=\"ninja_column_3 ninja_clmn_nm_role \">Role<\/th><th scope=\"col\"  class=\"ninja_column_4 ninja_clmn_nm_year \">Year<\/th><th scope=\"col\"  class=\"ninja_column_5 ninja_clmn_nm_amountinlakhsinr \">Amount  (in Lakhs INR)<\/th><\/tr>\n<\/thead>\n<tbody>\n\n<\/tbody><!--ninja_tobody_rendering_done-->\n    <\/table>\n    \n    \n    \n<\/div>\n                    <\/div>\n\t\t        \n                    <div id=\"book-or-book-chapters-tab\" class=\"clearfix eael-tab-content-item inactive\" data-title-link=\"book-or-book-chapters-tab\">\n\t\t\t\t        <div id=\"footable_parent_1881\"\n         class=\" footable_parent ninja_table_wrapper loading_ninja_table wp_table_data_press_parent semantic_ui \">\n                <table data-ninja_table_instance=\"ninja_table_instance_2\" data-footable_id=\"1881\" data-filter-delay=\"1000\" aria-label=\"Books_MSB\"            id=\"footable_1881\"\n           data-unique_identifier=\"ninja_table_unique_id_4157753254_1881\"\n           class=\" foo-table ninja_footable foo_table_1881 ninja_table_unique_id_4157753254_1881 ui table  nt_type_legacy_table selectable striped vertical_centered  footable-paging-right ninja_table_pro\">\n                <colgroup>\n                            <col class=\"ninja_column_0 \">\n                            <col class=\"ninja_column_1 \">\n                            <col class=\"ninja_column_2 \">\n                            <col class=\"ninja_column_3 \">\n                            <col class=\"ninja_column_4 \">\n                    <\/colgroup>\n        <thead>\n<tr class=\"footable-header\">\n                                                                                        <th scope=\"col\"  class=\"ninja_column_0 ninja_clmn_nm_srno \">Sr. No.<\/th><th scope=\"col\"  class=\"ninja_column_1 ninja_clmn_nm_author \">Author<\/th><th scope=\"col\"  class=\"ninja_column_2 ninja_clmn_nm_titleofthebook \">Title of the Book<\/th><th scope=\"col\"  class=\"ninja_column_3 ninja_clmn_nm_publisher \">Publisher<\/th><th scope=\"col\"  class=\"ninja_column_4 ninja_clmn_nm_year \">Year<\/th><\/tr>\n<\/thead>\n<tbody>\n\n        <tr data-row_id=\"0\" class=\"ninja_table_row_0 nt_row_id_0\">\n            <td>1<\/td><td>Gajanan Jaiswal, Makarand Ballal<\/td><td>Condition Monitoring and Health Status Assessment of Transformer<\/td><td>LAP LAMBERT Academic Publishing Co. Ltd.<\/td><td>2021<\/td>        <\/tr>\n            <tr data-row_id=\"1\" class=\"ninja_table_row_1 nt_row_id_1\">\n            <td>2<\/td><td>Manish Wath, Makarand Ballal<\/td><td>Error Compensation Technique For Smart Industrial Metering System.<\/td><td>LAP LAMBERT Academic Publishing Co. Ltd.<\/td><td>2020<\/td>        <\/tr>\n            <tr data-row_id=\"2\" class=\"ninja_table_row_2 nt_row_id_2\">\n            <td>3<\/td><td>Gulamfaruk Surya, Makarand Ballal , Amrin Surya<\/td><td>Monitoring of Operating Induction Motors: An Experimental Design for Detection and Diagnosis of Incipient Faults Using A Simplified Novel Technique<\/td><td>LAP LAMBERT Academic Publishing Co. Ltd.<\/td><td>2020<\/td>        <\/tr>\n    <\/tbody><!--ninja_tobody_rendering_done-->\n    <\/table>\n    \n    \n    \n<\/div>\n                    <\/div>\n\t\t        \n                    <div id=\"patents-tab\" class=\"clearfix eael-tab-content-item inactive\" data-title-link=\"patents-tab\">\n\t\t\t\t        <div id=\"footable_parent_1951\"\n         class=\" footable_parent ninja_table_wrapper loading_ninja_table wp_table_data_press_parent semantic_ui \">\n                <table data-ninja_table_instance=\"ninja_table_instance_3\" data-footable_id=\"1951\" data-filter-delay=\"1000\" aria-label=\"MSB_Patents\"            id=\"footable_1951\"\n           data-unique_identifier=\"ninja_table_unique_id_902515989_1951\"\n           class=\" foo-table ninja_footable foo_table_1951 ninja_table_unique_id_902515989_1951 ui table  nt_type_legacy_table selectable striped vertical_centered  footable-paging-right ninja_table_pro\">\n                <colgroup>\n                            <col class=\"ninja_column_0 \">\n                            <col class=\"ninja_column_1 \">\n                            <col class=\"ninja_column_2 \">\n                            <col class=\"ninja_column_3 \">\n                            <col class=\"ninja_column_4 \">\n                    <\/colgroup>\n        <thead>\n<tr class=\"footable-header\">\n                                                                                        <th scope=\"col\"  class=\"ninja_column_0 ninja_clmn_nm_srno \">Sr. No.<\/th><th scope=\"col\"  class=\"ninja_column_1 ninja_clmn_nm_patenttitle \">Patent Title<\/th><th scope=\"col\"  class=\"ninja_column_2 ninja_clmn_nm_applicationnopatentno \">Application No. (Patent No.)<\/th><th scope=\"col\"  class=\"ninja_column_3 ninja_clmn_nm_datepublishedgrant \">Date Published \/Grant<\/th><th scope=\"col\"  class=\"ninja_column_4 ninja_clmn_nm_presentstaus \">Present Staus<\/th><\/tr>\n<\/thead>\n<tbody>\n\n        <tr data-row_id=\"0\" class=\"ninja_table_row_0 nt_row_id_0\">\n            <td><\/td><td>NATIONAL PATENTS      <\/td><td><\/td><td><\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"1\" class=\"ninja_table_row_1 nt_row_id_1\">\n            <td>1<\/td><td>Model for the Analysis of Different Faults\/ Abnormal Condition of Transformer and Induction Motor<\/td><td>201621021851 (437028)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"2\" class=\"ninja_table_row_2 nt_row_id_2\">\n            <td>2<\/td><td>Induction Motor Incipient Fault Detection Maneuver<\/td><td>3966\/MUM\/2013 (421614)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"3\" class=\"ninja_table_row_3 nt_row_id_3\">\n            <td>3<\/td><td>Induction Motor Incipient Fault Detection Maneuver<\/td><td>201721001242 (394522)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"4\" class=\"ninja_table_row_4 nt_row_id_4\">\n            <td>4<\/td><td>Breather Condition MonitoringSystem For Transformers (BRECOMS-T)<\/td><td>201621041390 (392755)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"5\" class=\"ninja_table_row_5 nt_row_id_5\">\n            <td>5<\/td><td>A System for Monitoring, Controlling, Metering and Protection of Distributed Generation<\/td><td>1502\/MUM\/2014 (376588)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"6\" class=\"ninja_table_row_6 nt_row_id_6\">\n            <td>6<\/td><td>Online Error Compensation Methodology for Utilities and Industrial Metering System<\/td><td>2840\/MUM\/2013 (375135)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"7\" class=\"ninja_table_row_7 nt_row_id_7\">\n            <td>7<\/td><td>Hybrid Control of Resonant Converter for DC Grid Applications<\/td><td>201621001282 (357475)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"8\" class=\"ninja_table_row_8 nt_row_id_8\">\n            <td>8<\/td><td>Process and Methodology for the Development of Model for Analysis of Power Quality Index and Determination of Its Cause and Effects<\/td><td>839\/MUM\/2014 (348138)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"9\" class=\"ninja_table_row_9 nt_row_id_9\">\n            <td>9<\/td><td>Binary System Based On-Line Model for the Condition Monitoring of Power Transformers in Utilities and Consumer\u2019s Substations<\/td><td>1316\/MUM\/2013 (337043)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"10\" class=\"ninja_table_row_10 nt_row_id_10\">\n            <td>10<\/td><td>Remote Condition Monitoring System for Distribution Transformer (RCMS_DT)<\/td><td>3749\/MUM\/2014 (336105)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"11\" class=\"ninja_table_row_11 nt_row_id_11\">\n            <td>11<\/td><td>Status Monitoring Apparatus for Reactor and Transformer (SMART)<\/td><td>201621006484 (461379)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"12\" class=\"ninja_table_row_12 nt_row_id_12\">\n            <td>12<\/td><td>Transformer Test Bench (TTB)<\/td><td>201621026428 (473564)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"13\" class=\"ninja_table_row_13 nt_row_id_13\">\n            <td>13<\/td><td>A process for online condition monitoring for static and dynamic electrical machines<\/td><td>383\/MUM\/2014 (524684)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"14\" class=\"ninja_table_row_14 nt_row_id_14\">\n            <td>14<\/td><td>An adaptable multiport bidirectional renewable energy source integrated dc-dc converter<\/td><td>202221018254 (541316)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"15\" class=\"ninja_table_row_15 nt_row_id_15\">\n            <td>15<\/td><td>Machines\u2019 monitoring, control and protection system (M2CPS)<\/td><td>3381\/MUM\/2015 (545423)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"16\" class=\"ninja_table_row_16 nt_row_id_16\">\n            <td>16<\/td><td>A multi-port bidirectional non-isolated integrator and distributor system for green hydrogen production<\/td><td>202221045035 (562957)<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"17\" class=\"ninja_table_row_17 nt_row_id_17\">\n            <td><\/td><td>INTERNATIONAL PATENTS<\/td><td><\/td><td><\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"18\" class=\"ninja_table_row_18 nt_row_id_18\">\n            <td>17<\/td><td>A System for the Power Quality Indices Determination with their Causes and Effects<\/td><td>&#8230;&#8230;&#8230;.. (2021\/10618)                       South Africa<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"19\" class=\"ninja_table_row_19 nt_row_id_19\">\n            <td>18<\/td><td>A System for Better Operation of Multi-Microgrid<\/td><td>&#8230;&#8230;&#8230;.. (2022\/01418)                   South Africa<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"20\" class=\"ninja_table_row_20 nt_row_id_20\">\n            <td>19<\/td><td>Digital Error Compensation of Industrial Energy Measurement System<\/td><td>2021103474 (2021103474) Australian<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"21\" class=\"ninja_table_row_21 nt_row_id_21\">\n            <td>20<\/td><td>Application of SIPS for Effective Management of Power<\/td><td>&#8230;&#8230;&#8230;.. (202022100304) Germany<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"22\" class=\"ninja_table_row_22 nt_row_id_22\">\n            <td>21<\/td><td>Intelligent Condition Monitoring System for Distributed Transformer<\/td><td>2021107478 (2021107478) Australian<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"23\" class=\"ninja_table_row_23 nt_row_id_23\">\n            <td>22<\/td><td>Solar Energy Management for Agriculture and Rural Transformation (SMART)<\/td><td>2021103175 (2021103175) Australian<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n            <tr data-row_id=\"24\" class=\"ninja_table_row_24 nt_row_id_24\">\n            <td>23<\/td><td>A Multi Microgrid System<\/td><td>2020102128 (2020102128) Australian<\/td><td><\/td><td>Granted<\/td>        <\/tr>\n    <\/tbody><!--ninja_tobody_rendering_done-->\n    <\/table>\n    \n    \n    \n<\/div>\n                    <\/div>\n\t\t        \n                    <div id=\"sttp-workshop-tab\" class=\"clearfix eael-tab-content-item inactive\" data-title-link=\"sttp-workshop-tab\">\n\t\t\t\t        <div id=\"footable_parent_563\"\n         class=\" footable_parent ninja_table_wrapper loading_ninja_table wp_table_data_press_parent semantic_ui \">\n                <table data-ninja_table_instance=\"ninja_table_instance_4\" data-footable_id=\"563\" data-filter-delay=\"1000\" aria-label=\"79\"            id=\"footable_563\"\n           data-unique_identifier=\"ninja_table_unique_id_2826783532_563\"\n           class=\" foo-table ninja_footable foo_table_563 ninja_table_unique_id_2826783532_563 ui table  nt_type_legacy_table selectable striped vertical_centered  footable-paging-right ninja_table_pro\">\n                <colgroup>\n                            <col class=\"ninja_column_0 \">\n                            <col class=\"ninja_column_1 \">\n                            <col class=\"ninja_column_2 \">\n                            <col class=\"ninja_column_3 \">\n                            <col class=\"ninja_column_4 \">\n                    <\/colgroup>\n        <thead>\n<tr class=\"footable-header\">\n                                                                                        <th scope=\"col\"  class=\"ninja_column_0 ninja_clmn_nm_title \">Title<\/th><th scope=\"col\"  class=\"ninja_column_1 ninja_clmn_nm_fundingagency \">Funding Agency<\/th><th scope=\"col\"  class=\"ninja_column_2 ninja_clmn_nm_hostinstitute \">Host Institute<\/th><th scope=\"col\"  class=\"ninja_column_3 ninja_clmn_nm_dates \">Dates<\/th><th scope=\"col\"  class=\"ninja_column_4 ninja_clmn_nm_noofparticipants \">No. of Participants<\/th><\/tr>\n<\/thead>\n<tbody>\n\n        <tr data-row_id=\"0\" class=\"ninja_table_row_0 nt_row_id_0\">\n            <td>Sr. No.<\/td><td>Details of workshop<\/td><td>Organized at<\/td><td>Sponsored by \/ Self Sponsored<\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"1\" class=\"ninja_table_row_1 nt_row_id_1\">\n            <td>1<\/td><td>Shifting Teaching Learning Paradigms through Innovative Pedagogy (Duration: 12\/02\/2019 to 16\/02\/2019)<\/td><td>VNIT, Nagpur<\/td><td>Sponsored by TEQIP III and IEEE Bombay Section<\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"2\" class=\"ninja_table_row_2 nt_row_id_2\">\n            <td>3<\/td><td>Emerging Trends in Power System, Instrumentation and Control (Duration: 03\/10\/2016 to 07\/10\/2016)<\/td><td>VNIT, Nagpur<\/td><td>Sponsored by Govt. College of Engineering, Chandrapur (Under TEQIP)<\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"3\" class=\"ninja_table_row_3 nt_row_id_3\">\n            <td>5<\/td><td>Phase I- Condition Monitoring of Transformer (Duration: 06\/03\/2014 to 08\/03\/2014) Phase II- Condition Monitoring of Transformers and Induction Motors (Duration: 27\/03\/2015 to 28\/03\/2015)<\/td><td>VNIT, Nagpur<\/td><td>Sponsored by TEQIP-II<\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"4\" class=\"ninja_table_row_4 nt_row_id_4\">\n            <td>6<\/td><td>Phase I- Power Electronics in Power systems  (Duration: 06\/02\/2014 to 08\/02\/2014) Phase II- Smart Grid Applications  (Duration: 08\/01\/2015 to 09\/01\/2015)<\/td><td>VNIT, Nagpur<\/td><td>Sponsored by TEQIP-II<\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"5\" class=\"ninja_table_row_5 nt_row_id_5\">\n            <td>4<\/td><td>Power Electronics Applications in Micro-grids: enabling green Energy (Duration: 06\/04\/2016 to 10\/04\/2016)<\/td><td>VNIT, Nagpur<\/td><td>Sponsored by C-DAC, Trivandrum (Under NampeT)<\/td><td><\/td>        <\/tr>\n            <tr data-row_id=\"6\" class=\"ninja_table_row_6 nt_row_id_6\">\n            <td>7<\/td><td>Phase I- Lab-view: Programming and DAQ device Interfacing and Applications (Duration: 08\/08\/2014 to 09\/08\/2014) Phase II- OPAL-RT: Interfacing and Application (Duration: 18\/09\/2014 to 19\/09\/2014)<\/td><td>VNIT, Nagpur<\/td><td>Sponsored by TEQIP-II<\/td><td><\/td>        <\/tr>\n    <\/tbody><!--ninja_tobody_rendering_done-->\n    <\/table>\n    \n    \n    \n<\/div>\n                    <\/div>\n\t\t        \n                    <div id=\"administrative-responsibilities-tab\" class=\"clearfix eael-tab-content-item inactive\" data-title-link=\"administrative-responsibilities-tab\">\n\t\t\t\t        <div id=\"footable_parent_564\"\n         class=\" footable_parent ninja_table_wrapper loading_ninja_table wp_table_data_press_parent semantic_ui \">\n                <table data-ninja_table_instance=\"ninja_table_instance_5\" data-footable_id=\"564\" data-filter-delay=\"1000\" aria-label=\"710\"            id=\"footable_564\"\n           data-unique_identifier=\"ninja_table_unique_id_2451491429_564\"\n           class=\" foo-table ninja_footable foo_table_564 ninja_table_unique_id_2451491429_564 ui table  nt_type_legacy_table selectable striped vertical_centered  footable-paging-right ninja_table_pro\">\n                <colgroup>\n                            <col class=\"ninja_column_0 \">\n                            <col class=\"ninja_column_1 \">\n                            <col class=\"ninja_column_2 \">\n                    <\/colgroup>\n        <thead>\n<tr class=\"footable-header\">\n                                                        <th scope=\"col\"  class=\"ninja_column_0 ninja_clmn_nm_srno \">Sr. No.<\/th><th scope=\"col\"  class=\"ninja_column_1 ninja_clmn_nm_responsibility \">Responsibility<\/th><th scope=\"col\"  class=\"ninja_column_2 ninja_clmn_nm_year \">Year<\/th><\/tr>\n<\/thead>\n<tbody>\n\n        <tr data-row_id=\"0\" class=\"ninja_table_row_0 nt_row_id_0\">\n            <td>1<\/td><td>Head of Electrical Engineering Department<\/td><td>2025 onwards<\/td>        <\/tr>\n            <tr data-row_id=\"1\" class=\"ninja_table_row_1 nt_row_id_1\">\n            <td>2<\/td><td>Associate Dean, Electrical Maintenance, VNIT<\/td><td>2018-2021<\/td>        <\/tr>\n            <tr data-row_id=\"2\" class=\"ninja_table_row_2 nt_row_id_2\">\n            <td>3<\/td><td>Dept. Exam Controller (DEC), EED<\/td><td>July 2015-July 2017.<\/td>        <\/tr>\n            <tr data-row_id=\"3\" class=\"ninja_table_row_3 nt_row_id_3\">\n            <td>4<\/td><td>Faculty Coordinator of Student Mentor Program<\/td><td>2016-2017.<\/td>        <\/tr>\n            <tr data-row_id=\"4\" class=\"ninja_table_row_4 nt_row_id_4\">\n            <td>5<\/td><td>Industry Institute Interaction Organizer <\/td><td> July 2013- June 2015.<\/td>        <\/tr>\n    <\/tbody><!--ninja_tobody_rendering_done-->\n    <\/table>\n    \n    \n    \n<\/div>\n                    <\/div>\n\t\t        \n                    <div id=\"awards-honors-tab\" class=\"clearfix eael-tab-content-item inactive\" data-title-link=\"awards-honors-tab\">\n\t\t\t\t        <div id=\"footable_parent_565\"\n         class=\" footable_parent ninja_table_wrapper loading_ninja_table wp_table_data_press_parent semantic_ui \">\n                <table data-ninja_table_instance=\"ninja_table_instance_6\" data-footable_id=\"565\" data-filter-delay=\"1000\" aria-label=\"711\"            id=\"footable_565\"\n           data-unique_identifier=\"ninja_table_unique_id_540143257_565\"\n           class=\" foo-table ninja_footable foo_table_565 ninja_table_unique_id_540143257_565 ui table  nt_type_legacy_table selectable striped vertical_centered  footable-paging-right ninja_table_pro\">\n                <colgroup>\n                            <col class=\"ninja_column_0 \">\n                            <col class=\"ninja_column_1 \">\n                    <\/colgroup>\n        <thead>\n<tr class=\"footable-header\">\n                                        <th scope=\"col\"  class=\"ninja_column_0 ninja_clmn_nm_year \">Year<\/th><th scope=\"col\"  class=\"ninja_column_1 ninja_clmn_nm_awards \">Awards<\/th><\/tr>\n<\/thead>\n<tbody>\n\n        <tr data-row_id=\"0\" class=\"ninja_table_row_0 nt_row_id_0\">\n            <td>2023<\/td><td>Top 2% of the World&#8217;s Scientists by Stanford University<\/td>        <\/tr>\n            <tr data-row_id=\"1\" class=\"ninja_table_row_1 nt_row_id_1\">\n            <td>2024<\/td><td>Adviser UPSC<\/td>        <\/tr>\n            <tr data-row_id=\"2\" class=\"ninja_table_row_2 nt_row_id_2\">\n            <td>2017<\/td><td>Best Paper Award and Gold Medal from the Ministry of Power<\/td>        <\/tr>\n            <tr data-row_id=\"3\" class=\"ninja_table_row_3 nt_row_id_3\">\n            <td>2018<\/td><td>POSOCO Award to his Student for Ph D Dessertation PPSA-2017 Power Grid competition awardee for best doctoral research in WEST zone for thesis title &#8220;Diagnosis of incipient fault development in transformer by condition monitoring.&#8221;<\/td>        <\/tr>\n            <tr data-row_id=\"4\" class=\"ninja_table_row_4 nt_row_id_4\">\n            <td>2022<\/td><td>Fellow of the Institution of Engineers (FIE)<\/td>        <\/tr>\n            <tr data-row_id=\"5\" class=\"ninja_table_row_5 nt_row_id_5\">\n            <td>2018<\/td><td>Senior Member of IEEE<\/td>        <\/tr>\n            <tr data-row_id=\"6\" class=\"ninja_table_row_6 nt_row_id_6\">\n            <td>2009<\/td><td>The subject prize is received for the paper titled Measurement Current Transformer Error Compensation by ANN Methodology ( published in the Series B Journal of IEI, Vol. 100, Issue 3) at the Prize Distribution Ceremony of the 36th Indian Engineering Congress.<\/td>        <\/tr>\n            <tr data-row_id=\"7\" class=\"ninja_table_row_7 nt_row_id_7\">\n            <td>2002-06<\/td><td>Recipient of best paper presentation award (First Prize) from Institution of Engineers (India), Nagpur in Annual Technical paper Meet during 2002, 2003, and 2006.<\/td>        <\/tr>\n            <tr data-row_id=\"8\" class=\"ninja_table_row_8 nt_row_id_8\">\n            <td>2000<\/td><td>Recipient of 3rd Prize for best paper presentation award from Institution of Engineers (India), Nagpur in Annual Technical paper Meet in the year 2000.<\/td>        <\/tr>\n            <tr data-row_id=\"9\" class=\"ninja_table_row_9 nt_row_id_9\">\n            <td>2018<\/td><td>\u00d8 Track Chair for the IEEE PEDES conference held at IIT Madras, Chennai from 18 \u2013 21, Dec.2018.<\/td>        <\/tr>\n            <tr data-row_id=\"10\" class=\"ninja_table_row_10 nt_row_id_10\">\n            <td>2020<\/td><td>\u00d8 Member of 1st IEEE International Conference organized on STPEC, 2020, VNIT, Nagpur.<\/td>        <\/tr>\n            <tr data-row_id=\"11\" class=\"ninja_table_row_11 nt_row_id_11\">\n            <td>2019<\/td><td>Track Chair for the 45th IECON 2019 , Lisbon, Portugal<\/td>        <\/tr>\n            <tr data-row_id=\"12\" class=\"ninja_table_row_12 nt_row_id_12\">\n            <td>2018<\/td><td>Session chair and member in All India Seminar on \u201cGreen Energy &amp; Challenges over Smart Grid\u201d held at Nagpur on 10th -11th March 2018.<\/td>        <\/tr>\n            <tr data-row_id=\"13\" class=\"ninja_table_row_13 nt_row_id_13\">\n            <td>2017<\/td><td>Member of NPEC, 2017, CoE Pune.<\/td>        <\/tr>\n            <tr data-row_id=\"14\" class=\"ninja_table_row_14 nt_row_id_14\">\n            <td>2008-2011<\/td><td> Member of R&amp;D Committee of MSETCL by Executive Director (STU), MSETCL, Mumbai.<\/td>        <\/tr>\n            <tr data-row_id=\"15\" class=\"ninja_table_row_15 nt_row_id_15\">\n            <td>2009<\/td><td>Nominated as PhD and ME supervisor by RTM Nagpur University, Nagpur and Dr Babasaheb Ambedkar Marathwada University, Aurangabad, Gondwana University, Gadchiroli.<\/td>        <\/tr>\n            <tr data-row_id=\"16\" class=\"ninja_table_row_16 nt_row_id_16\">\n            <td>2007<\/td><td>\u00d8 A jury of State Level Technical Paper Conference, \u201cTechno Arena 2007\u201d, held at GoEC, Jalgaon on Feb. 23, 2008.<\/td>        <\/tr>\n            <tr data-row_id=\"17\" class=\"ninja_table_row_17 nt_row_id_17\">\n            <td>2009<\/td><td>\u00d8 Member of International Conference, \u201cGeneration Economics and Grid safe\u201d, organized by IE (I) Nagpur, Feb. 08-09, 2008.<\/td>        <\/tr>\n            <tr data-row_id=\"18\" class=\"ninja_table_row_18 nt_row_id_18\">\n            <td>2023<\/td><td>\u00d8 Session chair PESGRE 2023 Conference held in Trivendrum during 17- 20 December 2023<\/td>        <\/tr>\n    <\/tbody><!--ninja_tobody_rendering_done-->\n    <\/table>\n    \n    \n    \n<\/div>\n                    <\/div>\n\t\t        \n                    <div id=\"journal-publications-tab\" class=\"clearfix eael-tab-content-item inactive\" data-title-link=\"journal-publications-tab\">\n\t\t\t\t        <div id=\"footable_parent_1230\"\n         class=\" footable_parent ninja_table_wrapper loading_ninja_table wp_table_data_press_parent semantic_ui \">\n                <table data-ninja_table_instance=\"ninja_table_instance_7\" data-footable_id=\"1230\" data-filter-delay=\"1000\" aria-label=\"JP_MSB\"            id=\"footable_1230\"\n           data-unique_identifier=\"ninja_table_unique_id_1010512381_1230\"\n           class=\" foo-table ninja_footable foo_table_1230 ninja_table_unique_id_1010512381_1230 ui table  nt_type_legacy_table selectable striped vertical_centered  footable-paging-right ninja_table_pro\">\n                <colgroup>\n                            <col class=\"ninja_column_0 \">\n                            <col class=\"ninja_column_1 \">\n                    <\/colgroup>\n        <thead>\n<tr class=\"footable-header\">\n                                        <th scope=\"col\"  class=\"ninja_column_0 ninja_clmn_nm_sno \">S.No.<\/th><th scope=\"col\"  class=\"ninja_column_1 ninja_clmn_nm_papercitation \">Paper Citation<\/th><\/tr>\n<\/thead>\n<tbody>\n\n        <tr data-row_id=\"0\" class=\"ninja_table_row_0 nt_row_id_0\">\n            <td>1<\/td><td>Ballal, M. S., Verma, S. R., Suryawanshi, H. M., Wakode, S. A., &amp; Mishra, M. K. (2024). Resilient and Adaptive Power Integrator and Despatcher. IEEE Transactions on Industrial Informatics, 1\u201310. https:\/\/doi.org\/10.1109\/tii.2024.3359422<\/td>        <\/tr>\n            <tr data-row_id=\"1\" class=\"ninja_table_row_1 nt_row_id_1\">\n            <td>2<\/td><td>Dongare, U. V., Umre, B. S., Ballal, M. S., &amp; Dongare, V. P. (2023). Online Inter-Turn Fault Detection in Wound Rotor Induction Motors Based on VI Loci Pattern. IEEE Transactions on Industry Applications, 1\u201314. https:\/\/doi.org\/10.1109\/tia.2023.3324631<\/td>        <\/tr>\n            <tr data-row_id=\"2\" class=\"ninja_table_row_2 nt_row_id_2\">\n            <td>3<\/td><td>Dongare, U., Umre, B., &amp; Ballal, M. (2023). Stator inter-turn short-circuit fault diagnosis in induction motors applying VI loci-based technique. Energy Reports, 9, 1483\u20131493. https:\/\/doi.org\/10.1016\/j.egyr.2023.06.043<\/td>        <\/tr>\n            <tr data-row_id=\"3\" class=\"ninja_table_row_3 nt_row_id_3\">\n            <td>4<\/td><td>Dongare, U. V., Umre, B. S., &amp; Ballal, M. S. (2023). Voltage\u2013current locus\u2010based stator winding inter\u2010turn fault detection in induction motors. International Journal of Circuit Theory and Applications, 51(6), 2889\u20132911. https:\/\/doi.org\/10.1002\/cta.3561<\/td>        <\/tr>\n            <tr data-row_id=\"4\" class=\"ninja_table_row_4 nt_row_id_4\">\n            <td>5<\/td><td>Khond, S. R., Kale, V. S., &amp; Ballal, M. S. (2023). Detection of Bad Data and Estimation of Missing Parameter Values Using System Synergism. IEEE Transactions on Industry Applications, 59(5), 5646\u20135658. https:\/\/doi.org\/10.1109\/tia.2023.3276350<\/td>        <\/tr>\n            <tr data-row_id=\"5\" class=\"ninja_table_row_5 nt_row_id_5\">\n            <td>6<\/td><td>Verma, S. R., Ballal, M. S., Suryawanshi, H. M., Deshmukh, R. R., &amp; Wakode, S. A. (2023a). Power pool\u2010based supervisory coordinate control strategy for DC microgrids. International Journal of Circuit Theory and Applications, 51(12), 5724\u20135742. https:\/\/doi.org\/10.1002\/cta.3725<\/td>        <\/tr>\n            <tr data-row_id=\"6\" class=\"ninja_table_row_6 nt_row_id_6\">\n            <td>7<\/td><td>Khond, S., Kale, V., &amp; Ballal, M. S. (2023). Non-pilot accelerated trip for distance relays using total relative reactance change in Zone II. Electric Power Systems Research, 218, 109171. https:\/\/doi.org\/10.1016\/j.epsr.2023.109171<\/td>        <\/tr>\n            <tr data-row_id=\"7\" class=\"ninja_table_row_7 nt_row_id_7\">\n            <td>8<\/td><td>Wakode, S. A., Ballal, M. S., &amp; Deshmukh, R. R. (2022). Sliding DFT-Based Fault Location Scheme for DC Microgrid. IEEE Transactions on Industry Applications, 58(5), 5944\u20135954. https:\/\/doi.org\/10.1109\/tia.2022.3189610<\/td>        <\/tr>\n            <tr data-row_id=\"8\" class=\"ninja_table_row_8 nt_row_id_8\">\n            <td>9<\/td><td>Ballal, M. S., Verma, S. R., Suryawanshi, H. M., Deshmukh, R. R., Wakode, S. A., &amp; Mishra, M. K. (2022). An Improved Voltage Regulation and Effective Power Management by Coordinated Control Scheme in Multibus DC Microgrid. IEEE Access, 10, 72301\u201372311. https:\/\/doi.org\/10.1109\/access.2022.3189473<\/td>        <\/tr>\n            <tr data-row_id=\"9\" class=\"ninja_table_row_9 nt_row_id_9\">\n            <td>10<\/td><td>Dongare, U. V., Umre, B. S., &amp; Ballal, M. S. (2022). Rotor winding inter-turn short-circuit fault detection in wound rotor induction motors using Wing Technique. Journal of Power Electronics\/Journal of Power Electronics, 22(4), 614\u2013628. https:\/\/doi.org\/10.1007\/s43236-022-00382-5<\/td>        <\/tr>\n            <tr data-row_id=\"10\" class=\"ninja_table_row_10 nt_row_id_10\">\n            <td>11<\/td><td>Ballal, M. S., &amp; Kulkarni, A. R. (2021). Integrating synchrophasor technology for the improvements in system integrity protection schemes under stressed conditions. Sadhana\/Sa\u0304Dhana\u0304, 46(4). https:\/\/doi.org\/10.1007\/s12046-021-01711-3<\/td>        <\/tr>\n            <tr data-row_id=\"11\" class=\"ninja_table_row_11 nt_row_id_11\">\n            <td>12<\/td><td>Bhadane, K. V., Ballal, M. S., Nayyar, A., Patil, D. P., Jaware, T. H., &amp; Shukla, H. P. (2020). A Comprehensive Study of Harmonic Pollution in Large Penetrated Grid-Connected Wind Farm. Mapan\/M\u0100PAN. Journal of Metrology Society of India, 36(4), 729\u2013749. https:\/\/doi.org\/10.1007\/s12647-020-00407-z<\/td>        <\/tr>\n            <tr data-row_id=\"12\" class=\"ninja_table_row_12 nt_row_id_12\">\n            <td>13<\/td><td>Ballal, M. S. (2021). Online Electrical Energy Theft Detection and Prevention Scheme for Direct Hook-line Activity. Journal of Institution of Engineers (India) Series B, 102(5), 1007\u20131018. https:\/\/doi.org\/10.1007\/s40031-021-00616-3<\/td>        <\/tr>\n            <tr data-row_id=\"13\" class=\"ninja_table_row_13 nt_row_id_13\">\n            <td>14<\/td><td>Wakode, S. A., Ballal, M. S., Sheikh, A. A., &amp; Deshmukh, R. R. (2021). Oscillation Frequency Component-Based Protection Scheme for DC Microgrid. IEEE Transactions on Industry Applications, 57(6), 5747\u20135757. https:\/\/doi.org\/10.1109\/tia.2021.3115089<\/td>        <\/tr>\n            <tr data-row_id=\"14\" class=\"ninja_table_row_14 nt_row_id_14\">\n            <td>15<\/td><td>Kulkarni, A. R., &amp; Ballal, M. S. (2021). Synergism of synchrophasor measurements and data analytics for enhancing situational awareness of power grid. Computers &amp; Electrical Engineering, 93, 107231. https:\/\/doi.org\/10.1016\/j.compeleceng.2021.107231<\/td>        <\/tr>\n            <tr data-row_id=\"15\" class=\"ninja_table_row_15 nt_row_id_15\">\n            <td>16<\/td><td>Deshmukh, R. R., &amp; Ballal, M. S. (2021). Improved Dynamic Response of DC Microgrid Under Transient Condition Using Inertia by Virtual Generation. IEEE Access, 9, 86739\u201386750. https:\/\/doi.org\/10.1109\/access.2021.3089325<\/td>        <\/tr>\n            <tr data-row_id=\"16\" class=\"ninja_table_row_16 nt_row_id_16\">\n            <td>17<\/td><td>Ballal, M. S., Kulkarni, A. R., &amp; Suryawanshi, H. M. (2021). Methodology for the improvements in synchrophasor based System Integrity Protection Schemes under stressed conditions. Sustainable Energy, Grids and Networks, 26, 100465. https:\/\/doi.org\/10.1016\/j.segan.2021.100465<\/td>        <\/tr>\n            <tr data-row_id=\"17\" class=\"ninja_table_row_17 nt_row_id_17\">\n            <td>18<\/td><td>Patankar, P. P., Munshi, M. M., Deshmukh, R. R., &amp; Ballal, M. S. (2021). A Modified Control Method for Grid Connected Multiple Rooftop Solar Power Plants. IEEE Transactions on Industry Applications, 57(4), 3306\u20133316. https:\/\/doi.org\/10.1109\/tia.2021.3075195<\/td>        <\/tr>\n            <tr data-row_id=\"18\" class=\"ninja_table_row_18 nt_row_id_18\">\n            <td>19<\/td><td>Ballal, M. S., &amp; Kulkarni, A. R. (2021a). Synergizing PMU Data From Multiple Locations in Indian Power Grid-Case Study. IEEE Access, 9, 63980\u201363994. https:\/\/doi.org\/10.1109\/access.2021.3074562<\/td>        <\/tr>\n            <tr data-row_id=\"19\" class=\"ninja_table_row_19 nt_row_id_19\">\n            <td>20<\/td><td>Ballal, M. S., Kulkarni, A. R., &amp; Suryawanshi, H. M. (2020). Operational experience and performance evaluation of some of the system integrity and protection schemes. Electrical Engineering, 103(2), 1155\u20131167. https:\/\/doi.org\/10.1007\/s00202-020-01154-9<\/td>        <\/tr>\n            <tr data-row_id=\"20\" class=\"ninja_table_row_20 nt_row_id_20\">\n            <td>21<\/td><td>Ballal, M. S., &amp; Kulkarni, A. R. (2021a). Improvements in Existing System Integrity Protection Schemes Under Stressed Conditions by Synchrophasor Technology\u2014Case Studies. IEEE Access, 9, 20788\u201320807. https:\/\/doi.org\/10.1109\/access.2021.3054792<\/td>        <\/tr>\n            <tr data-row_id=\"21\" class=\"ninja_table_row_21 nt_row_id_21\">\n            <td>22<\/td><td>Bhadane, K. V., Ballal, M. S., Moharil, R. M., Kulkarni, H. R., &amp; Prasad, H. (2021). Enhancement of fault ride-through capability of grid-connected wind farm. International Journal of Power Electronics, 13(3), 267. https:\/\/doi.org\/10.1504\/ijpelec.2021.114467<\/td>        <\/tr>\n            <tr data-row_id=\"22\" class=\"ninja_table_row_22 nt_row_id_22\">\n            <td>23<\/td><td>Deshmukh, R. R., &amp; Ballal, M. S. (2020). A Comprehensive Control Scheme for the Effective Power Management Based on Power Pools in DC Microgrid. https:\/\/doi.org\/10.1109\/pedes49360.2020.9379653<\/td>        <\/tr>\n            <tr data-row_id=\"23\" class=\"ninja_table_row_23 nt_row_id_23\">\n            <td>24<\/td><td>Deshmukh, R. R., &amp; Ballal, M. S. (2020a). Integrated control scheme for dynamic power management with improved voltage regulation in DC microgrid. Journal of Power Electronics\/Journal of Power Electronics, 20(6), 1550\u20131561. https:\/\/doi.org\/10.1007\/s43236-020-00152-1<\/td>        <\/tr>\n            <tr data-row_id=\"24\" class=\"ninja_table_row_24 nt_row_id_24\">\n            <td>25<\/td><td>Ballal, M. S., Suryawanshi, H., Mishra, M. K., &amp; Jaiswal, G. (2020). Online electricity theft detection and prevention scheme for smart cities. IET Smart Cities, 2(3), 155\u2013164. https:\/\/doi.org\/10.1049\/iet-smc.2020.0045<\/td>        <\/tr>\n            <tr data-row_id=\"25\" class=\"ninja_table_row_25 nt_row_id_25\">\n            <td>26<\/td><td>Ballal, M., Kulkarni, A., &amp; Suryawanshi, H. (2020). Data compression techniques for Phasor Measurement Unit (PMU) applications in smart transmission grid. International Journal of Emerging Electric Power Systems, 21(3). https:\/\/doi.org\/10.1515\/ijeeps-2019-0266<\/td>        <\/tr>\n            <tr data-row_id=\"26\" class=\"ninja_table_row_26 nt_row_id_26\">\n            <td>27<\/td><td>Jaiswal, S., &amp; Ballal, M. S. (2020). Fuzzy inference based irrigation controller for agricultural demand side management. Computers and Electronics in Agriculture, 175, 105537. https:\/\/doi.org\/10.1016\/j.compag.2020.105537<\/td>        <\/tr>\n            <tr data-row_id=\"27\" class=\"ninja_table_row_27 nt_row_id_27\">\n            <td>28<\/td><td>Deshmukh, R. R., Ballal, M. S., &amp; Suryawanshi, H. M. (2020). A Fuzzy Logic Based Supervisory Control for Power Management in Multibus DC Microgrid. IEEE Transactions on Industry Applications, 56(6), 6174\u20136185. https:\/\/doi.org\/10.1109\/tia.2020.3012415<\/td>        <\/tr>\n            <tr data-row_id=\"28\" class=\"ninja_table_row_28 nt_row_id_28\">\n            <td>29<\/td><td>Ballal, M. S., Wath, M. G., &amp; Suryawanshi, H. M. (2020). Measurement Current Transformer Error Compensation by ANN Methodology. Journal of Institution of Engineers (India) Series B, 101(3), 261\u2013271. https:\/\/doi.org\/10.1007\/s40031-020-00454-9<\/td>        <\/tr>\n            <tr data-row_id=\"29\" class=\"ninja_table_row_29 nt_row_id_29\">\n            <td>30<\/td><td>Ballal, M. S., Wath, M. G., &amp; Suryawanshi, H. M. (2020a). Design and Development of Industrial Energy Measurement Error Compensation Unit. Electric Power Components and Systems, 48(8), 799\u2013816. https:\/\/doi.org\/10.1080\/15325008.2020.1821830<\/td>        <\/tr>\n            <tr data-row_id=\"30\" class=\"ninja_table_row_30 nt_row_id_30\">\n            <td>31<\/td><td>Jaiswal, S., &amp; Ballal, M. S. (2020a). Fuzzy Inference Based Electricity Theft Prevention System to Restrict Direct Tapping Over Distribution Line. Journal of Electrical Engineering &amp; Technology\/Journal of Electrical Engineering &amp; Technology, 15(3), 1095\u20131106. https:\/\/doi.org\/10.1007\/s42835-020-00408-7<\/td>        <\/tr>\n            <tr data-row_id=\"31\" class=\"ninja_table_row_31 nt_row_id_31\">\n            <td>32<\/td><td>Reddy, V. V., Suryawanshi, H. M., Talapur, G. G., Nachankar, P. P., &amp; Ballal, M. S. (2020). Design and implementation of high efficient dual control modular resonant converter for DC microgrid. IET Power Electronics, 13(7), 1381\u20131392. https:\/\/doi.org\/10.1049\/iet-pel.2019.0726<\/td>        <\/tr>\n            <tr data-row_id=\"32\" class=\"ninja_table_row_32 nt_row_id_32\">\n            <td>33<\/td><td>P, V. V. R., Suryawanshi, H. M., Nachankar, P. P., Talapur, G. G., &amp; Ballal, M. S. (2019). Modular\u2010structured resonant converter for multilevel converters in micro grids. International Journal of Circuit Theory and Applications, 48(1), 134\u2013147. https:\/\/doi.org\/10.1002\/cta.2716<\/td>        <\/tr>\n            <tr data-row_id=\"33\" class=\"ninja_table_row_33 nt_row_id_33\">\n            <td>34<\/td><td>P, V. V. R., Suryawanshi, H. M., Talapur, G. G., &amp; Ballal, M. S. (2019). Optimized Resonant Converter by Implementing Shunt Branch Element as Magnetizing Inductance of Transformer in Electric Vehicle Chargers. IEEE Transactions on Industry Applications, 55(6), 7471\u20137480. https:\/\/doi.org\/10.1109\/tia.2019.2933783<\/td>        <\/tr>\n            <tr data-row_id=\"34\" class=\"ninja_table_row_34 nt_row_id_34\">\n            <td>35<\/td><td>Jaiswal, G. C., Ballal, M. S., Tutakne, &amp; Suryawanshi, H. M. (2019). Impact of Power Quality on the Performance of Distribution Transformers: A Fuzzy Logic Approach to Assessing Power Quality. IEEE Industry Applications Magazine, 25(5), 8\u201317. https:\/\/doi.org\/10.1109\/mias.2018.2875207<\/td>        <\/tr>\n            <tr data-row_id=\"35\" class=\"ninja_table_row_35 nt_row_id_35\">\n            <td>36<\/td><td>Ballal, M. S., &amp; Wath, M. G. (2019). Current Transformer Accuracy Improvement by Digital Compensation Technique. Mapan\/M\u0100PAN. Journal of Metrology Society of India, 34(2), 225\u2013237. https:\/\/doi.org\/10.1007\/s12647-019-00304-0<\/td>        <\/tr>\n            <tr data-row_id=\"36\" class=\"ninja_table_row_36 nt_row_id_36\">\n            <td>37<\/td><td>Deshmukh, R. R., Ballal, M. S., Suryawanshi, H. M., &amp; Mishra, M. K. (2020). An Adaptive Approach for Effective Power Management in DC Microgrid Based on Virtual Generation in Distributed Energy Sources. IEEE Transactions on Industrial Informatics, 16(1), 362\u2013372. https:\/\/doi.org\/10.1109\/tii.2019.2919647<\/td>        <\/tr>\n            <tr data-row_id=\"37\" class=\"ninja_table_row_37 nt_row_id_37\">\n            <td>38<\/td><td>Ballal, M. S., &amp; Wath, M. G. (2019a). LabVIEW\u2010based real\u2010time error compensation system for measurement current transformer using piecewise linearisation. IET Science, Measurement &amp; Technology, 13(1), 74\u201382. https:\/\/doi.org\/10.1049\/iet-smt.2018.5107<\/td>        <\/tr>\n            <tr data-row_id=\"38\" class=\"ninja_table_row_38 nt_row_id_38\">\n            <td>39<\/td><td>Ballal, M. S., Wath, M. G., &amp; Suryawanshi, H. M. (2019). A Novel Approach for the Error Correction of CT in the Presence of Harmonic Distortion. IEEE Transactions on Instrumentation and Measurement, 68(10), 4015\u20134027. https:\/\/doi.org\/10.1109\/tim.2018.2884575<\/td>        <\/tr>\n            <tr data-row_id=\"39\" class=\"ninja_table_row_39 nt_row_id_39\">\n            <td>40<\/td><td>Ballal, M. S., Suryawanshi, H. M., &amp; Koshy, S. E. (2018). Model for Analysis of Power Quality Index and Determination of Its Causes and Effects. Journal of Institution of Engineers (India) Series B, 99(5), 493\u2013508. https:\/\/doi.org\/10.1007\/s40031-018-0340-x<\/td>        <\/tr>\n            <tr data-row_id=\"40\" class=\"ninja_table_row_40 nt_row_id_40\">\n            <td>41<\/td><td>Jaiswal, S., &amp; Ballal, M. S. (2018). Method for fixing harmonic injection share of utility or consumer or both at the point of energy metering. IET Generation, Transmission &amp; Distribution, 12(16), 3803\u20133811. https:\/\/doi.org\/10.1049\/iet-gtd.2018.0249<\/td>        <\/tr>\n            <tr data-row_id=\"41\" class=\"ninja_table_row_41 nt_row_id_41\">\n            <td>42<\/td><td>Jaiswal, G. C., Ballal, M. S., Venikar, P. A., Tutakne, D. R., &amp; Suryawanshi, H. M. (2018). Genetic algorithm-based health index determination of distribution transformer. International Transactions on Electrical Energy Systems, 28(5), e2529. https:\/\/doi.org\/10.1002\/etep.2529<\/td>        <\/tr>\n            <tr data-row_id=\"42\" class=\"ninja_table_row_42 nt_row_id_42\">\n            <td>43<\/td><td>&#8220;2017 Index IEEE Transactions on Power Delivery Vol. 32,&#8221; in IEEE Transactions on Power Delivery, vol. 32, no. 6, pp. 1-36, Dec. 2017, doi: 10.1109\/TPWRD.2017.2785663.<\/td>        <\/tr>\n            <tr data-row_id=\"43\" class=\"ninja_table_row_43 nt_row_id_43\">\n            <td>44<\/td><td>Sathyan, S., Suryawanshi, H. M., Shitole, A. B., Ballal, M. S., &amp; Borghate, V. B. (2018). Soft-Switched Interleaved DC\/DC Converter as Front-End of Multi-Inverter Structure for Micro Grid Applications. IEEE Transactions on Power Electronics, 33(9), 7645\u20137655. https:\/\/doi.org\/10.1109\/tpel.2017.2768379<\/td>        <\/tr>\n            <tr data-row_id=\"44\" class=\"ninja_table_row_44 nt_row_id_44\">\n            <td>45<\/td><td>Shitole, A. B., Suryawanshi, H. M., Sathyan, S., Talapur, G. G., &amp; Ballal, M. S. (2017). A Comparative Performance Evaluation of Extended AANF with Different Parameter Estimation Techniques for Renewable Energy Integration. Electric Power Components and Systems, 45(17), 1870\u20131880. https:\/\/doi.org\/10.1080\/15325008.2017.1378945<\/td>        <\/tr>\n            <tr data-row_id=\"45\" class=\"ninja_table_row_45 nt_row_id_45\">\n            <td>46<\/td><td>Suryawanshi, H. M., Pachpor, S., Ajmal, T., Talapur, G. G., Sathyan, S., Ballal, M. S., Borghate, V. B., &amp; Ramteke, M. R. (2018). Hybrid Control of High-Efficient Resonant Converter for Renewable Energy System. IEEE Transactions on Industrial Informatics, 14(5), 1835\u20131845. https:\/\/doi.org\/10.1109\/tii.2017.2756703<\/td>        <\/tr>\n            <tr data-row_id=\"46\" class=\"ninja_table_row_46 nt_row_id_46\">\n            <td>47<\/td><td>Ballal, M. S., Jaiswal, G. C., Tutkane, D. R., Venikar, P. A., Mishra, M. K., &amp; Suryawanshi, H. M. (2017). Online condition monitoring system for substation and service transformers. IET Electric Power Applications, 11(7), 1187\u20131195. https:\/\/doi.org\/10.1049\/iet-epa.2016.0842<\/td>        <\/tr>\n            <tr data-row_id=\"47\" class=\"ninja_table_row_47 nt_row_id_47\">\n            <td>48<\/td><td>Vilhekar, T. G., Ballal, M. S., &amp; Suryawanshi, H. M. (2017). Detection of Winding Faults in Wound Rotor Induction Motor Using Loci of Direct and Quadrature Axes of Rotor Currents. Electric Power Components and Systems, 1\u201314. https:\/\/doi.org\/10.1080\/15325008.2017.1334102<\/td>        <\/tr>\n            <tr data-row_id=\"48\" class=\"ninja_table_row_48 nt_row_id_48\">\n            <td>49<\/td><td>Jaiswal, S., &amp; Ballal, M. S. (2017a). FDST\u2010based PQ event detection and energy metering implementation on FPGA\u2010in\u2010the\u2010loop and NI\u2010LabVIEW. IET Science, Measurement &amp; Technology, 11(4), 453\u2013463. https:\/\/doi.org\/10.1049\/iet-smt.2016.0481<\/td>        <\/tr>\n            <tr data-row_id=\"49\" class=\"ninja_table_row_49 nt_row_id_49\">\n            <td>50<\/td><td>Sathyan, S., Suryawanshi, H. M., Ballal, M. S., &amp; Shitole, A. B. (2017). Low switching stress DC-DC converter with capability of high voltage gain for low voltage energy sources. EPE Journal, 27(2), 74\u201384. https:\/\/doi.org\/10.1080\/09398368.2017.1317137<\/td>        <\/tr>\n            <tr data-row_id=\"50\" class=\"ninja_table_row_50 nt_row_id_50\">\n            <td>51<\/td><td>Venikar, P. A., Ballal, M. S., Umre, B. S., &amp; Suryawanshi, H. M. (2017). Search Coil based Online Diagnostics of Transformer Internal Faults. IEEE Transactions on Power Delivery, 1. https:\/\/doi.org\/10.1109\/tpwrd.2017.2682083<\/td>        <\/tr>\n            <tr data-row_id=\"51\" class=\"ninja_table_row_51 nt_row_id_51\">\n            <td>52<\/td><td>Shitole, A. B., Suryawanshi, H. M., Talapur, G. G., Sathyan, S., Ballal, M. S., Borghate, V. B., Ramteke, M. R., &amp; Chaudhari, M. A. (2017). Grid Interfaced Distributed Generation System With Modified Current Control Loop Using Adaptive Synchronization Technique. IEEE Transactions on Industrial Informatics, 13(5), 2634\u20132644. https:\/\/doi.org\/10.1109\/tii.2017.2665477<\/td>        <\/tr>\n            <tr data-row_id=\"52\" class=\"ninja_table_row_52 nt_row_id_52\">\n            <td>53<\/td><td>Vilhekar, T. G., Ballal, M. S., &amp; Suryawanshi, H. M. (2017a). Application of Multiple Parks Vector Approach for Detection of Multiple Faults in Induction Motors. 17(4), 972\u2013982. http:\/\/dspace.kci.go.kr\/handle\/kci\/950362<\/td>        <\/tr>\n            <tr data-row_id=\"53\" class=\"ninja_table_row_53 nt_row_id_53\">\n            <td>54<\/td><td>2016 Index IEEE Transactions on Power Delivery Vol. 31. (2016). IEEE Transactions on Power Delivery, 31(6), 1\u201338. https:\/\/doi.org\/10.1109\/tpwrd.2016.2642498<\/td>        <\/tr>\n            <tr data-row_id=\"54\" class=\"ninja_table_row_54 nt_row_id_54\">\n            <td>55<\/td><td>Venikar, P. A., Ballal, M. S., Umre, B. S., &amp; Suryawanshi, H. M. (2016). Sensitive incipient inter\u2010turn fault detection algorithm for power transformers. IET Electric Power Applications, 10(9), 858\u2013868. https:\/\/doi.org\/10.1049\/iet-epa.2016.0059<\/td>        <\/tr>\n            <tr data-row_id=\"55\" class=\"ninja_table_row_55 nt_row_id_55\">\n            <td>56<\/td><td>Surya, G. N., Khan, Z. J., Ballal, M. S., &amp; Suryawanshi, H. M. (2017). A Simplified Frequency-Domain Detection of Stator Turn Fault in Squirrel-Cage Induction Motors Using an Observer Coil Technique. IEEE Transactions on Industrial Electronics, 64(2), 1495\u20131506. https:\/\/doi.org\/10.1109\/tie.2016.2611585<\/td>        <\/tr>\n            <tr data-row_id=\"56\" class=\"ninja_table_row_56 nt_row_id_56\">\n            <td>57<\/td><td>Sathyan, S., Suryawanshi, H. M., Singh, B., Chakraborty, C., Verma, V., &amp; Ballal, M. S. (2016). ZVS\u2013ZCS High Voltage Gain Integrated Boost Converter for DC Microgrid. IEEE Transactions on Industrial Electronics, 63(11), 6898\u20136908. https:\/\/doi.org\/10.1109\/tie.2016.2582460<\/td>        <\/tr>\n            <tr data-row_id=\"57\" class=\"ninja_table_row_57 nt_row_id_57\">\n            <td>58<\/td><td>Ballal, M. S., Suryawanshi, H. M., Ballal, D. M., &amp; Mishra, M. K. (2014). Special Protection Scheme at BTPS Power Station. Journal of Institution of Engineers (India) Series B, 97(1), 97\u2013107. https:\/\/doi.org\/10.1007\/s40031-014-0169-x<\/td>        <\/tr>\n            <tr data-row_id=\"58\" class=\"ninja_table_row_58 nt_row_id_58\">\n            <td>59<\/td><td>Chaudhari, B. N., &amp; Ballal, M. S. (2016). Remote condition Monitoring Technique of Transformer using single board computer. International Journal of Engineering Trends and Technology, 32(6), 275\u2013280. https:\/\/doi.org\/10.14445\/22315381\/ijett-v32p255<\/td>        <\/tr>\n            <tr data-row_id=\"59\" class=\"ninja_table_row_59 nt_row_id_59\">\n            <td>60<\/td><td>Kulkarni, A., Rajurkar, S., &amp; Ballal. (2016). Transmission sector Development and adoption of SMARTGRID technologies in Indian scenario. Water and Energy International, 4, 18\u201323. http:\/\/www.indianjournals.com\/ijor.aspx?target=ijor:wei&amp;volume=59r&amp;issue=4&amp;article=003<\/td>        <\/tr>\n            <tr data-row_id=\"60\" class=\"ninja_table_row_60 nt_row_id_60\">\n            <td>61<\/td><td>Ballal, M. S., Bhadane, K. V., Moharil, R. M., &amp; Suryawanshi, H. M. (2016). A Control and Protection Model for the Distributed Generation and Energy Storage Systems in Microgrids. Journal of Power Electronics\/Journal of Power Electronics, 16(2), 748\u2013759. https:\/\/doi.org\/10.6113\/jpe.2016.16.2.748<\/td>        <\/tr>\n            <tr data-row_id=\"61\" class=\"ninja_table_row_61 nt_row_id_61\">\n            <td>62<\/td><td>Bhadane, K. V., Ballal, M. S., &amp; Moharil, R. M. (2015). Enhancement of Distributed Generation by Using Custom Power Device. 13(3), 246\u2013254. https:\/\/doi.org\/10.11989\/jest.1674-862x.505262<\/td>        <\/tr>\n            <tr data-row_id=\"62\" class=\"ninja_table_row_62 nt_row_id_62\">\n            <td>63<\/td><td>Ballal, M. S., Suryawanshi, H. M., Mishra, M. K., &amp; Chaudhari, B. N. (2016). Interturn Faults Detection of Transformers by Diagnosis of Neutral Current. IEEE Transactions on Power Delivery, 31(3), 1096\u20131105. https:\/\/doi.org\/10.1109\/tpwrd.2015.2461433<\/td>        <\/tr>\n            <tr data-row_id=\"63\" class=\"ninja_table_row_63 nt_row_id_63\">\n            <td>64<\/td><td>Sathyan, S., Suryawanshi, H. M., Ballal, M. S., &amp; Shitole, A. B. (2015). Soft-Switching DC\u2013DC Converter for Distributed Energy Sources With High Step-Up Voltage Capability. IEEE Transactions on Industrial Electronics, 62(11), 7039\u20137050. https:\/\/doi.org\/10.1109\/tie.2015.2448515<\/td>        <\/tr>\n            <tr data-row_id=\"64\" class=\"ninja_table_row_64 nt_row_id_64\">\n            <td>65<\/td><td>Venikar, P. A., Ballal, M. S., Umre, B. S., &amp; Suryawanshi, H. M. (2016a). A Novel Offline to Online Approach to Detect Transformer Interturn Fault. IEEE Transactions on Power Delivery, 31(2), 482\u2013492. https:\/\/doi.org\/10.1109\/tpwrd.2015.2440448<\/td>        <\/tr>\n            <tr data-row_id=\"65\" class=\"ninja_table_row_65 nt_row_id_65\">\n            <td>66<\/td><td>Keswani, R. A., Suryawanshi, H. M., &amp; Ballal, M. S. (2015). Multi\u2010resolution analysis for converter switch faults identification. IET Power Electronics, 8(5), 783\u2013792. https:\/\/doi.org\/10.1049\/iet-pel.2014.0450<\/td>        <\/tr>\n            <tr data-row_id=\"66\" class=\"ninja_table_row_66 nt_row_id_66\">\n            <td>67<\/td><td>Kulkarni, A. R., Kelkar, S. G., Rajurkar, S. S., &amp; Ballal. (2015). Towards smarter transmission grid: Mahatransco Experience. 28(2), 10\u201317. http:\/\/www.indianjournals.com\/ijor.aspx?target=ijor:jiaegtd&amp;volume=28&amp;issue=2&amp;article=002<\/td>        <\/tr>\n            <tr data-row_id=\"67\" class=\"ninja_table_row_67 nt_row_id_67\">\n            <td>68<\/td><td>Balla, M. S., Suryawanshi, H. M., &amp; Choudhari, B. N. (2015). Extended Wing Technique Approach for the Detection of Winding Interturn Faults in Three-phase Transformers. Journal of Power Electronics\/Journal of Power Electronics, 15(1), 288\u2013297. https:\/\/doi.org\/10.6113\/jpe.2015.15.1.288<\/td>        <\/tr>\n            <tr data-row_id=\"68\" class=\"ninja_table_row_68 nt_row_id_68\">\n            <td>69<\/td><td>Ballal, M. S., Ballal, D. M., Suryawanshi, H. M., &amp; Mishra, M. K. (2014). Corrective Measures for the Effective Load Management and Control Under Disturbance at Bhusawal Thermal Power Station: Case Study. Journal of Institution of Engineers (India) Series B, 95(2), 163\u2013173. https:\/\/doi.org\/10.1007\/s40031-014-0082-3<\/td>        <\/tr>\n            <tr data-row_id=\"69\" class=\"ninja_table_row_69 nt_row_id_69\">\n            <td>70<\/td><td>Ballal, M. S., Suryawanshi, H. M., &amp; Reddy, T. V. (2012). Mitigation of Voltage Dip and Voltage Flickering by Multilevel D-STATCOM. Advances in Power Electronics, 2012, 1\u201311. https:\/\/doi.org\/10.1155\/2012\/871652<\/td>        <\/tr>\n            <tr data-row_id=\"70\" class=\"ninja_table_row_70 nt_row_id_70\">\n            <td>71<\/td><td>Ballal, M. S., &amp; Suryawanshi, H. M. (2012). Corrective Measures in Islanding Scheme at Bhusawal Thermal Power Station &#8211; Case Study. International Journal of Emerging Electric Power Systems, 13(2). https:\/\/doi.org\/10.1515\/1553-779x.2930<\/td>        <\/tr>\n            <tr data-row_id=\"71\" class=\"ninja_table_row_71 nt_row_id_71\">\n            <td>72<\/td><td>Ballal, M. S., Ballal, D. M., Suryawanshi, H. M., &amp; Mishra, M. K. (2012). Wing Technique: A Novel Approach for the Detection of Stator Winding Inter-Turn Short Circuit and Open Circuit Faults in Three Phase Induction Motors. Journal of Power Electronics\/Journal of Power Electronics, 12(1), 208\u2013214. https:\/\/doi.org\/10.6113\/jpe.2012.12.1.208<\/td>        <\/tr>\n            <tr data-row_id=\"72\" class=\"ninja_table_row_72 nt_row_id_72\">\n            <td>73<\/td><td>Ballal, Makarand &amp; Ballal, D.M. &amp; Suryawanshi, Hiralal. (2010). Impact of power quality on the performance of induction motor. Journal of the Institution of Engineers (India): Electrical Engineering Division. 90. 63-68.<\/td>        <\/tr>\n            <tr data-row_id=\"73\" class=\"ninja_table_row_73 nt_row_id_73\">\n            <td>74<\/td><td>Ballal, M. S., Suryawanshi, H. M., &amp; Mishra, M. K. (2009). ANN based real time incipient fault detection and protection system for induction motor. International Journal of Power and Energy Conversion, 1(2\/3), 125. https:\/\/doi.org\/10.1504\/ijpec.2009.027940<\/td>        <\/tr>\n            <tr data-row_id=\"74\" class=\"ninja_table_row_74 nt_row_id_74\">\n            <td>75<\/td><td>Ballal, M. S., Suryawanshi, H. M., &amp; Mishra, M. K. (2008). Stator Winding Inter-turn Insulation Fault Detection in Induction Motors by Symmetrical Components Method. Electric Power Components and Systems, 36(7), 741\u2013753. https:\/\/doi.org\/10.1080\/15325000701881993<\/td>        <\/tr>\n            <tr data-row_id=\"75\" class=\"ninja_table_row_75 nt_row_id_75\">\n            <td>76<\/td><td>Ballal, M. S., Ballal, D. M., &amp; Suryawanshi, H. M. (2008). Fuzzy system for the detection of power quality performance on induction motor. http:\/\/yadda.icm.edu.pl\/yadda\/element\/bwmeta1.element.baztech-cb81f049-eee4-4998-acb1-0532089063bd<\/td>        <\/tr>\n            <tr data-row_id=\"76\" class=\"ninja_table_row_76 nt_row_id_76\">\n            <td>77<\/td><td>Ballal, M. S., Suryawanshi, H. M., &amp; Mishra, M. K. (2008a). Detection of Incipient Faults in Induction Motors using FIS, ANN and ANFIS Techniques. 8(2), 181\u2013191. https:\/\/jpels.org\/digital-library\/17459<\/td>        <\/tr>\n            <tr data-row_id=\"77\" class=\"ninja_table_row_77 nt_row_id_77\">\n            <td>78<\/td><td>Ballal, M. S., Khan, Z. J., Suryawanshi, H. M., &amp; Sonolikar, R. L. (2007). Adaptive Neural Fuzzy Inference System for the Detection of Inter-Turn Insulation and Bearing Wear Faults in Induction Motor. IEEE Transactions on Industrial Electronics, 54(1), 250\u2013258. https:\/\/doi.org\/10.1109\/tie.2006.888789<\/td>        <\/tr>\n            <tr data-row_id=\"78\" class=\"ninja_table_row_78 nt_row_id_78\">\n            <td>79<\/td><td>Ballal, Suryawanshi, H., &amp; Mishra, M. K. (2007b). ANN Based System for the Detection of Winding Insulation Condition and Bearing Wear in Single Phase Induction Motor. Journal of Electrical Engineering &amp; Technology\/Journal of Electrical Engineering &amp; Technology, 2(4), 485\u2013493. https:\/\/doi.org\/10.5370\/jeet.2007.2.4.485<\/td>        <\/tr>\n            <tr data-row_id=\"79\" class=\"ninja_table_row_79 nt_row_id_79\">\n            <td>80<\/td><td>Ballal, M. S., Khan, Z. J., Suryawanshi, H. M., &amp; Sonolikar, R. L. (2006). Induction Motor: Fuzzy System for the Detection of Winding Insulation Condition and Bearing Wear. Electric Power Components and Systems, 34(2), 159\u2013171. https:\/\/doi.org\/10.1080\/15325000500244625<\/td>        <\/tr>\n            <tr data-row_id=\"80\" class=\"ninja_table_row_80 nt_row_id_80\">\n            <td>81<\/td><td>Ballal, Makarand &amp; Khan, Z.J.. (2005). ANN based stator winding inter-turn insulation level detector for single phase induction motor. 86. 103-106.<\/td>        <\/tr>\n    <\/tbody><!--ninja_tobody_rendering_done-->\n    <\/table>\n    \n    \n    \n<\/div>\n                    <\/div>\n\t\t        \n                    <div id=\"conference-publications-tab\" class=\"clearfix eael-tab-content-item inactive\" data-title-link=\"conference-publications-tab\">\n\t\t\t\t        <div id=\"footable_parent_1226\"\n         class=\" footable_parent ninja_table_wrapper loading_ninja_table wp_table_data_press_parent semantic_ui \">\n                <table data-ninja_table_instance=\"ninja_table_instance_8\" data-footable_id=\"1226\" data-filter-delay=\"1000\" aria-label=\"CP_MSB\"            id=\"footable_1226\"\n           data-unique_identifier=\"ninja_table_unique_id_1730509362_1226\"\n           class=\" foo-table ninja_footable foo_table_1226 ninja_table_unique_id_1730509362_1226 ui table  nt_type_legacy_table selectable striped vertical_centered  footable-paging-right ninja_table_pro\">\n                <colgroup>\n                            <col class=\"ninja_column_0 \">\n                            <col class=\"ninja_column_1 \">\n                    <\/colgroup>\n        <thead>\n<tr class=\"footable-header\">\n                                        <th scope=\"col\"  class=\"ninja_column_0 ninja_clmn_nm_sno \">S.No.<\/th><th scope=\"col\"  class=\"ninja_column_1 ninja_clmn_nm_papercitation \">Paper Citation<\/th><\/tr>\n<\/thead>\n<tbody>\n\n        <tr data-row_id=\"0\" class=\"ninja_table_row_0 nt_row_id_0\">\n            <td>1<\/td><td>Verma, S. R., Ballal, M. S., Suryawanshi, H. M., Deshmukh, R. R., &amp; Wakode, S. A. (2023). RES Integration and Load Dispatching System. https:\/\/doi.org\/10.1109\/pesgre58662.2023.10404942<\/td>        <\/tr>\n            <tr data-row_id=\"1\" class=\"ninja_table_row_1 nt_row_id_1\">\n            <td>2<\/td><td>Pattnaik, T., Kumar, M., &amp; Ballal, M. S. (2023). Predicting SoH and RUL of Li-ion Batteries in Electric Vehicles: A Comprehensive Review and Chemistry Insights. https:\/\/doi.org\/10.1109\/pesgre58662.2023.10404475<\/td>        <\/tr>\n            <tr data-row_id=\"2\" class=\"ninja_table_row_2 nt_row_id_2\">\n            <td>3<\/td><td>Garg, A., &amp; Ballal, M. S. (2023). SPARK Technology for Condition Monitoring of Solar Power Plants. https:\/\/doi.org\/10.1109\/pesgre58662.2023.10404111<\/td>        <\/tr>\n            <tr data-row_id=\"3\" class=\"ninja_table_row_3 nt_row_id_3\">\n            <td>4<\/td><td>Pattnaik, T., &amp; Ballal, M. S. (2023). Predictive Approach for Age and RUL Estimation of Lithium-Ion Batteries in EVs based on Capacitance. https:\/\/doi.org\/10.1109\/pesgre58662.2023.10404210<\/td>        <\/tr>\n            <tr data-row_id=\"4\" class=\"ninja_table_row_4 nt_row_id_4\">\n            <td>5<\/td><td>Kanaparthi, R. K., Singh, J. P., &amp; Ballal, M. S. (2023). A Switched Capacitor and Inductor based Ultra-High Gain DC &#8211; DC Converter with Staircase Structure for Renewable Energy Applications. https:\/\/doi.org\/10.1109\/pesgre58662.2023.10404445<\/td>        <\/tr>\n            <tr data-row_id=\"5\" class=\"ninja_table_row_5 nt_row_id_5\">\n            <td>6<\/td><td>Wakode, S. A., Ballal, M. S., &amp; Verma, S. R. (2023b). DC Series Arc Fault Detection Method for Multi-terminal DC Microgrid Using Sensors Error Compensation. https:\/\/doi.org\/10.1109\/pesgre58662.2023.10404173<\/td>        <\/tr>\n            <tr data-row_id=\"6\" class=\"ninja_table_row_6 nt_row_id_6\">\n            <td>7<\/td><td>Wath, M. G., &amp; Ballal, M. S. (2023). Optimizing Accuracy in Metering Cubicles: Case Studies of Online Error Correction. https:\/\/doi.org\/10.1109\/pesgre58662.2023.10405079<\/td>        <\/tr>\n            <tr data-row_id=\"7\" class=\"ninja_table_row_7 nt_row_id_7\">\n            <td>8<\/td><td>Kallalu, N., Wakekar, T., Kale, H., Sharma, G., Kumar, A., Verma, S. R., Wakode, S. A., &amp; Ballal, M. S. (2023). Effective Power Management and Stability Analysis of MIMO EV Charging Station. https:\/\/doi.org\/10.1109\/pesgre58662.2023.10404143<\/td>        <\/tr>\n            <tr data-row_id=\"8\" class=\"ninja_table_row_8 nt_row_id_8\">\n            <td>9<\/td><td>A. Garg, T. Pattnaik, S. R. Verma, M. S. Ballal, M. G. Wath and S. A. Wakode, &#8220;Addressing Challenges and Promoting Standardization in EVCS: A Review,&#8221; 2023 IEEE 3rd International Conference on Smart Technologies for Power, Energy and Control (STPEC), Bhubaneswar, India, 2023, pp. 1-6, doi: 10.1109\/STPEC59253.2023.10431268.<\/td>        <\/tr>\n            <tr data-row_id=\"9\" class=\"ninja_table_row_9 nt_row_id_9\">\n            <td>10<\/td><td>Bhardwaj, T., Kale, V. S., Ballal, M. S., &amp; Khond, S. (2023). Switched Inductor Based Cell Balancing Topology For String of Li-Ion Batteries. https:\/\/doi.org\/10.1109\/stpec59253.2023.10431389<\/td>        <\/tr>\n            <tr data-row_id=\"10\" class=\"ninja_table_row_10 nt_row_id_10\">\n            <td>11<\/td><td>Bhardwaj, T., Kale, V. S., Ballal, M. S., &amp; Khond, S. (2023a). Comparative Analysis of Machine Learning Models for Li-Ion Battery SoC Estimation. https:\/\/doi.org\/10.1109\/stpec59253.2023.10430560<\/td>        <\/tr>\n            <tr data-row_id=\"11\" class=\"ninja_table_row_11 nt_row_id_11\">\n            <td>12<\/td><td>Kumar, S., Ballal, M. S., Kulkarni, P. S., &amp; Sharma, P. K. (2023). Performance Study of 84.5 kWp Grid Linked SPV System. https:\/\/doi.org\/10.1109\/i2ct57861.2023.10126325<\/td>        <\/tr>\n            <tr data-row_id=\"12\" class=\"ninja_table_row_12 nt_row_id_12\">\n            <td>13<\/td><td>Pattnaik, T., Garg, A., Verma, S. R., Ballal, M. S., Wath, M. G., &amp; Wakode, S. A. (2023). Design of a Basic BMS: A Warning System. https:\/\/doi.org\/10.1109\/icnte56631.2023.10146650<\/td>        <\/tr>\n            <tr data-row_id=\"13\" class=\"ninja_table_row_13 nt_row_id_13\">\n            <td>14<\/td><td>Krishna, G. M. V. S., Ballal, M. S., Verma, S. R., Sharma, G., Kale, H. A., &amp; Naipunya, K. (2022). Integration of RES using Multiport DC-DC converter and Load Management. https:\/\/doi.org\/10.1109\/pedes56012.2022.10080066<\/td>        <\/tr>\n            <tr data-row_id=\"14\" class=\"ninja_table_row_14 nt_row_id_14\">\n            <td>15<\/td><td>Khond, S., Kale, V., &amp; Ballal, M. S. (2022). Modified Communication Assisted Line Differential Protection Scheme with Adaptive Machine Learning-Based Relay. https:\/\/doi.org\/10.1109\/pedes56012.2022.10080726<\/td>        <\/tr>\n            <tr data-row_id=\"15\" class=\"ninja_table_row_15 nt_row_id_15\">\n            <td>16<\/td><td>Khond, S., Kale, V., &amp; Ballal, M. S. (2022a). Machine Learning-based Modification of Communication Assisted TRIP Schemes deployed with Distance Relays. https:\/\/doi.org\/10.1109\/pedes56012.2022.10079985<\/td>        <\/tr>\n            <tr data-row_id=\"16\" class=\"ninja_table_row_16 nt_row_id_16\">\n            <td>17<\/td><td>R. K. Kanaparthi, J. P. Singh and M. S. Ballal, &#8220;A Review on Multi-Port Bidirectional Isolated and Non-Isolated DC-DC Converters for Renewable Applications,&#8221; 2022 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES), Jaipur, India, 2022, pp. 1-6, doi: 10.1109\/PEDES56012.2022.10080049.<\/td>        <\/tr>\n            <tr data-row_id=\"17\" class=\"ninja_table_row_17 nt_row_id_17\">\n            <td>18<\/td><td>Dongare, U., Umre, B., Ballal, M., &amp; Dongare, V. (2022). Design of Optimal MLP-Neural Network-based Induction Motor Fault Classifier. 2022 IEEE International Conference on Power Electronics, Smart Grid, and Renewable Energy (PESGRE). https:\/\/doi.org\/10.1109\/pesgre52268.2022.9715874<\/td>        <\/tr>\n            <tr data-row_id=\"18\" class=\"ninja_table_row_18 nt_row_id_18\">\n            <td>19<\/td><td>Khond, S., Kale, V., &amp; Ballal, M. S. (2022a). A combined Data Mining and Machine Learning approach for High Impedance Fault Detection in Microgrids. 2022 IEEE International Conference on Power Electronics, Smart Grid, and Renewable Energy (PESGRE). https:\/\/doi.org\/10.1109\/pesgre52268.2022.9715823<\/td>        <\/tr>\n            <tr data-row_id=\"19\" class=\"ninja_table_row_19 nt_row_id_19\">\n            <td>20<\/td><td>Khond, S., Kale, V., &amp; Ballal, M. S. (2022b). Data Mining Methods for Bad Data Detection and Event Data Acquisition in Microgrids. 2022 IEEE International Conference on Power Electronics, Smart Grid, and Renewable Energy (PESGRE). https:\/\/doi.org\/10.1109\/pesgre52268.2022.9715808<\/td>        <\/tr>\n            <tr data-row_id=\"20\" class=\"ninja_table_row_20 nt_row_id_20\">\n            <td>21<\/td><td>Wakode, S. A., Kumar, S., &amp; Ballal, M. S. (2021). A Flexible Protection Approach for DC Microgrid Using Wavelet based Machine Learning Technique. 2021 IEEE 2nd International Conference on Smart Technologies for Power, Energy and Control (STPEC). https:\/\/doi.org\/10.1109\/stpec52385.2021.9718684<\/td>        <\/tr>\n            <tr data-row_id=\"21\" class=\"ninja_table_row_21 nt_row_id_21\">\n            <td>22<\/td><td>Dongare, U., Umre, B., Ballal, M., &amp; Dongare, V. (2021). Incipient Faults Detection in Induction Motor using MLP-NN and RBF-NN-based Fault Classifier. 2021 IEEE 2nd International Conference on Smart Technologies for Power, Energy and Control (STPEC). https:\/\/doi.org\/10.1109\/stpec52385.2021.9718693<\/td>        <\/tr>\n            <tr data-row_id=\"22\" class=\"ninja_table_row_22 nt_row_id_22\">\n            <td>23<\/td><td>Kumar, S., Wakode, S. A., Ballal, M. S., Kanere, A., &amp; Parackal, P. (2021). Adaptive Protection Scheme for DC Microgrid to Avoid the False Tripping. 2021 IEEE 2nd International Conference on Smart Technologies for Power, Energy and Control (STPEC). https:\/\/doi.org\/10.1109\/stpec52385.2021.9718766<\/td>        <\/tr>\n            <tr data-row_id=\"23\" class=\"ninja_table_row_23 nt_row_id_23\">\n            <td>24<\/td><td>Deshmukh, R. R., &amp; Ballal, M. S. (2020b). A Comprehensive Control Scheme for the Effective Power Management Based on Power Pools in DC Microgrid. https:\/\/doi.org\/10.1109\/pedes49360.2020.9379653<\/td>        <\/tr>\n            <tr data-row_id=\"24\" class=\"ninja_table_row_24 nt_row_id_24\">\n            <td>25<\/td><td>Deshmukh, R. R., &amp; Ballal, M. S. (2020d). A Hierarchical Control Scheme for Electric Vehicle Charging Stations Coordinated Operation. https:\/\/doi.org\/10.1109\/pedes49360.2020.9379363<\/td>        <\/tr>\n            <tr data-row_id=\"25\" class=\"ninja_table_row_25 nt_row_id_25\">\n            <td>26<\/td><td>Verma, S. R., Ballal, M. S., Suryawanshi, H. M., Deshmukh, R. R., &amp; Singh, R. (2020). Power Sharing between DC Microgrids through Interlink Non-isolated Cluster Converter. https:\/\/doi.org\/10.1109\/pedes49360.2020.9379623<\/td>        <\/tr>\n            <tr data-row_id=\"26\" class=\"ninja_table_row_26 nt_row_id_26\">\n            <td>27<\/td><td>Sheikh, A. A., Wakode, S. A., Deshmukh, R. R., &amp; Ballal, M. S. (2020). Detection of High Impedance Fault in DC Microgrid. https:\/\/doi.org\/10.1109\/pedes49360.2020.9379409<\/td>        <\/tr>\n            <tr data-row_id=\"27\" class=\"ninja_table_row_27 nt_row_id_27\">\n            <td>28<\/td><td>Wakode, S. A., Ballal, M. S., &amp; Deshmukh, R. R. (2020). A New Protection Scheme for DC Microgrid using Numerical Computational Method. https:\/\/doi.org\/10.1109\/pedes49360.2020.9379634<\/td>        <\/tr>\n            <tr data-row_id=\"28\" class=\"ninja_table_row_28 nt_row_id_28\">\n            <td>29<\/td><td>Wakode, S. A., Ballal, M. S., Sheikh, A. A., &amp; Deshmukh, R. R. (2020). Novel Method to avoid the Tripping of Converter During Fault Condition in DC Microgrid. https:\/\/doi.org\/10.1109\/pedes49360.2020.9379379<\/td>        <\/tr>\n            <tr data-row_id=\"29\" class=\"ninja_table_row_29 nt_row_id_29\">\n            <td>30<\/td><td>Deshmukh, R. R., &amp; Ballal, M. S. (2020e). Hierarchical Control for Effective Power Management and to Improve Voltage Regulation in DC Multi-Microgrid System. https:\/\/doi.org\/10.1109\/pedes49360.2020.9379359<\/td>        <\/tr>\n            <tr data-row_id=\"30\" class=\"ninja_table_row_30 nt_row_id_30\">\n            <td>31<\/td><td>Dongare, U. V., Umre, B. S., &amp; Ballal, M. S. (2020). Mathematical Modeling and Simulation of an Induction Motor with Stator Inter-Turn Faults. 2020 IEEE First International Conference on Smart Technologies for Power, Energy and Control (STPEC). https:\/\/doi.org\/10.1109\/stpec49749.2020.9297711<\/td>        <\/tr>\n            <tr data-row_id=\"31\" class=\"ninja_table_row_31 nt_row_id_31\">\n            <td>32<\/td><td>Wath, M., Wath, H., Ballal, M., &amp; Jaiswal, G. (2020). Effect of Lockdown on KVAh Billing System &#8211;A Case Study. 2020 IEEE First International Conference on Smart Technologies for Power, Energy and Control (STPEC). https:\/\/doi.org\/10.1109\/stpec49749.2020.9297730<\/td>        <\/tr>\n            <tr data-row_id=\"32\" class=\"ninja_table_row_32 nt_row_id_32\">\n            <td>33<\/td><td>Jaiswal, G. C., Ballal, M. S., Surywanshi, H. M., &amp; Wath, M. (2020). Diagnostic Approach and Condition Monitoring Methods to Boost up the Reliability of Transformer. 2020 IEEE First International Conference on Smart Technologies for Power, Energy and Control (STPEC). https:\/\/doi.org\/10.1109\/stpec49749.2020.9297687<\/td>        <\/tr>\n            <tr data-row_id=\"33\" class=\"ninja_table_row_33 nt_row_id_33\">\n            <td>34<\/td><td>Sheikh, A. A., Wakode, S. A., Deshmukh, R. R., Ballal, M. S., Suryawanshi, H. M., Mishra, M. K., &amp; Kumar, S. (2020). A Brief Review on DC Microgrid Protection. 2020 IEEE First International Conference on Smart Technologies for Power, Energy and Control (STPEC). https:\/\/doi.org\/10.1109\/stpec49749.2020.9297770<\/td>        <\/tr>\n            <tr data-row_id=\"34\" class=\"ninja_table_row_34 nt_row_id_34\">\n            <td>35<\/td><td>Munshi, M. M., Patankar, P. P., Deshmukh, R. R., Kumar, S., &amp; Ballal, M. S. (2020). A Supervisory Control Scheme for Efficient Power Management and Seamless Transition in AC Microgrid. 2020 IEEE First International Conference on Smart Technologies for Power, Energy and Control (STPEC). https:\/\/doi.org\/10.1109\/stpec49749.2020.9297801<\/td>        <\/tr>\n            <tr data-row_id=\"35\" class=\"ninja_table_row_35 nt_row_id_35\">\n            <td>36<\/td><td>Kulkarni, A. R., &amp; Ballal, M. S. (2020). Ultra mega power plant disturbance related oscillation detection in Indian grid using PMU data. International Journal of Emerging Electric Power Systems, 21(4). https:\/\/doi.org\/10.1515\/ijeeps-2019-0178<\/td>        <\/tr>\n            <tr data-row_id=\"36\" class=\"ninja_table_row_36 nt_row_id_36\">\n            <td>37<\/td><td>Wakode, S. A., Sheikh, A. A., Deshmukh, R. R., &amp; Ballal, M. S. (2020). Oscillation Frequency Based Protection Scheme for Ring Type DC Microgrid. 2020 IEEE International Conference on Power Electronics, Smart Grid and Renewable Energy (PESGRE2020). https:\/\/doi.org\/10.1109\/pesgre45664.2020.9070592<\/td>        <\/tr>\n            <tr data-row_id=\"37\" class=\"ninja_table_row_37 nt_row_id_37\">\n            <td>38<\/td><td>Kulkarni, A. R., Rajurkar, S. S., &amp; Ballal, M. S. (2019). Wide Area Monitoring System (WAMS): The Foundation Block of Smartgrids for Event Analysis. In Lecture notes in electrical engineering (pp. 37\u201350). https:\/\/doi.org\/10.1007\/978-981-32-9119-5_4<\/td>        <\/tr>\n            <tr data-row_id=\"38\" class=\"ninja_table_row_38 nt_row_id_38\">\n            <td>39<\/td><td>Kulkarni, A. R., Ballal, M. S., &amp; Gautam, A. (2019). Operational Experience and Performance Evaluation of Prime System Integrity and Protection Schemes (SIPS) in India. https:\/\/doi.org\/10.1109\/icps48983.2019.9067632<\/td>        <\/tr>\n            <tr data-row_id=\"39\" class=\"ninja_table_row_39 nt_row_id_39\">\n            <td>40<\/td><td>Deshmukh, R. R., &amp; Ballal, M. S. (2019). A Supervisory Modified Control Scheme for Power Management in Multi Bus DC Microgrid. https:\/\/doi.org\/10.1109\/iecon.2019.8926999<\/td>        <\/tr>\n            <tr data-row_id=\"40\" class=\"ninja_table_row_40 nt_row_id_40\">\n            <td>41<\/td><td>Sheikh, A. A., Wakode, S. A., Deshmukh, R. R., &amp; Ballal, M. S. (2019). A Protection Scheme for Fault Detection, Location and Isolation in DC Ring Microgrid. https:\/\/doi.org\/10.1109\/iecon.2019.8927515<\/td>        <\/tr>\n            <tr data-row_id=\"41\" class=\"ninja_table_row_41 nt_row_id_41\">\n            <td>42<\/td><td>Ballal, M. S., Jaiswal, G. C., Doorwar, A., &amp; Venkatesh, B. (2019). Online Condition Assessment of Power Transformers using Neural Network. 2019 Innovations in Power and Advanced Computing Technologies (i-PACT). https:\/\/doi.org\/10.1109\/i-pact44901.2019.8960161<\/td>        <\/tr>\n            <tr data-row_id=\"42\" class=\"ninja_table_row_42 nt_row_id_42\">\n            <td>43<\/td><td>Jaiswal, S., &amp; Ballal, M. S. (2019). A Novel Online Technique for Fixing the Accountability of Harmonic Injector in Distribution Network. 2019 Innovations in Power and Advanced Computing Technologies (i-PACT). https:\/\/doi.org\/10.1109\/i-pact44901.2019.8960200<\/td>        <\/tr>\n            <tr data-row_id=\"43\" class=\"ninja_table_row_43 nt_row_id_43\">\n            <td>44<\/td><td>Talapur, G. G., Suryawanshi, H. M., Deshmukh, R. R., Ballal, M. S., &amp; Choudhary, R. (2018). Hybrid Control Technique for Load Sharing and Seamless Transition in Microgrid Mode of Operation. https:\/\/doi.org\/10.1109\/pedes.2018.8707454<\/td>        <\/tr>\n            <tr data-row_id=\"44\" class=\"ninja_table_row_44 nt_row_id_44\">\n            <td>45<\/td><td>Deshmukh, R. R., &amp; Ballal, M. S. (2018). A Power Management Algorithm for DC Microgrid Based on Virtual Storage in Source. https:\/\/doi.org\/10.1109\/pedes.2018.8707762<\/td>        <\/tr>\n            <tr data-row_id=\"45\" class=\"ninja_table_row_45 nt_row_id_45\">\n            <td>46<\/td><td>Jaiswal, G. C., Ballal, M. S., &amp; Renge, M. M. (2018). Condition Monitoring of Breather for Transformer Health Assessment. https:\/\/doi.org\/10.1109\/pedes.2018.8707896<\/td>        <\/tr>\n            <tr data-row_id=\"46\" class=\"ninja_table_row_46 nt_row_id_46\">\n            <td>47<\/td><td>Deshmukh, R. R., &amp; Ballal, M. S. (2018a). A Distributed Control for Adequate Power Sharing Based on Available Power in Sources. https:\/\/doi.org\/10.1109\/pedes.2018.8707518<\/td>        <\/tr>\n            <tr data-row_id=\"47\" class=\"ninja_table_row_47 nt_row_id_47\">\n            <td>48<\/td><td>Ballal, M. S., Wath, M. G., Suryawanshi, H. M., &amp; Venkatesh, B. (2018). Improvement of Current Transformer Accuracy by Digital Compensation Technique. https:\/\/doi.org\/10.1109\/pedes.2018.8707670<\/td>        <\/tr>\n            <tr data-row_id=\"48\" class=\"ninja_table_row_48 nt_row_id_48\">\n            <td>49<\/td><td>Kulkarni, A. R., &amp; Ballal, M. S. (2018). Indian Experience Of HVDC Event Analysis Using PMU Data. https:\/\/doi.org\/10.1109\/pedes.2018.8707807<\/td>        <\/tr>\n            <tr data-row_id=\"49\" class=\"ninja_table_row_49 nt_row_id_49\">\n            <td>50<\/td><td>Deshmukh, R. R., Ballal, M. S., Talapur, G. G., &amp; Suryawanshi, H. M. (2018). Distributed Control for Power Management Based on Fuzzy Logic in DC Microgrid. https:\/\/doi.org\/10.1109\/icpeices.2018.8897485<\/td>        <\/tr>\n            <tr data-row_id=\"50\" class=\"ninja_table_row_50 nt_row_id_50\">\n            <td>51<\/td><td>Wath, M. G., &amp; Ballal, M. S. (2018). Reactive Power Management in Roof -Top Solar Net Metering &#8211; Case study thereof. https:\/\/doi.org\/10.1109\/icsedps.2018.8536036<\/td>        <\/tr>\n            <tr data-row_id=\"51\" class=\"ninja_table_row_51 nt_row_id_51\">\n            <td>52<\/td><td>G. C. Jaiswal, M. S. Ballal, D. R. Tutakne and A. Doorwar, &#8220;A Review of Diagnostic Tests and Condition Monitoring Techniques for Improving the Reliability of Power Transformers,&#8221; 2018 International Conference on Smart Electric Drives and Power System (ICSEDPS), Nagpur, India, 2018, pp. 209-214, doi: 10.1109\/ICSEDPS.2018.8536067.<\/td>        <\/tr>\n            <tr data-row_id=\"52\" class=\"ninja_table_row_52 nt_row_id_52\">\n            <td>53<\/td><td>Deshmukh, R. R., &amp; Ballal, M. S. (2018a). An energy management scheme for grid connected EVs charging stations. https:\/\/doi.org\/10.1109\/picc.2018.8384741<\/td>        <\/tr>\n            <tr data-row_id=\"53\" class=\"ninja_table_row_53 nt_row_id_53\">\n            <td>54<\/td><td>Wath, M. G., &amp; Ballal, M. S. (2018a). Design of standard revenue energy meter for electrical locomotive (Railway traction). https:\/\/doi.org\/10.1109\/picc.2018.8384820<\/td>        <\/tr>\n            <tr data-row_id=\"54\" class=\"ninja_table_row_54 nt_row_id_54\">\n            <td>55<\/td><td>Jaiswal, G. C., Ballal, M. S., Tutakne, &amp; Vishnu, P. (2018). Intelligent condition monitoring system for distribution transformer and health status diagnosis. https:\/\/doi.org\/10.1109\/picc.2018.8384786<\/td>        <\/tr>\n            <tr data-row_id=\"55\" class=\"ninja_table_row_55 nt_row_id_55\">\n            <td>56<\/td><td>Kulkarni, A. R., Ballal, M. S., &amp; Rajurkar, S. S. (2018). Developing SMARTGRID Projects with Global Perspective in Indian Scenario. In Lecture notes in electrical engineering (pp. 3\u201317). https:\/\/doi.org\/10.1007\/978-981-10-8249-8_1<\/td>        <\/tr>\n            <tr data-row_id=\"56\" class=\"ninja_table_row_56 nt_row_id_56\">\n            <td>57<\/td><td>Kulkarni, A. R., Ballal, M. S., &amp; Rajurkar, S. S. (2017). Utilisation of PMU data for event analysis: Indian case study. 2017 7th International Conference on Power Systems (ICPS). https:\/\/doi.org\/10.1109\/icpes.2017.8387394<\/td>        <\/tr>\n            <tr data-row_id=\"57\" class=\"ninja_table_row_57 nt_row_id_57\">\n            <td>58<\/td><td>Jaiswal, S., Ballal, M. S., Kashif, S. M., &amp; Meena, R. (2017). Demand side load management using GSM enabled smart energy meter. 2017 7th International Conference on Power Systems (ICPS). https:\/\/doi.org\/10.1109\/icpes.2017.8387267<\/td>        <\/tr>\n            <tr data-row_id=\"58\" class=\"ninja_table_row_58 nt_row_id_58\">\n            <td>59<\/td><td>Jaiswal, G. C., Ballal, M. S., &amp; Tutakne, D. R. (2017). ANN based methodology for determination of distribution transformer health status. 2017 7th International Conference on Power Systems (ICPS). https:\/\/doi.org\/10.1109\/icpes.2017.8387281<\/td>        <\/tr>\n            <tr data-row_id=\"59\" class=\"ninja_table_row_59 nt_row_id_59\">\n            <td>60<\/td><td>Deshmukh, R. R., Ballal, M. S., Suryawanshi, H. M., &amp; Talapur, G. G. (2017). A control algorithm for energy management and transient mitigation in DC microgrid. https:\/\/doi.org\/10.1109\/npec.2017.8310470<\/td>        <\/tr>\n            <tr data-row_id=\"60\" class=\"ninja_table_row_60 nt_row_id_60\">\n            <td>61<\/td><td>Surya, G. N., Ballal, M. S., &amp; Khan, Z. J. (2017). Application of observer coil technique for detection of stator turn fault and damaged bearing in cage motors. https:\/\/doi.org\/10.1109\/npec.2017.8310474<\/td>        <\/tr>\n            <tr data-row_id=\"61\" class=\"ninja_table_row_61 nt_row_id_61\">\n            <td>62<\/td><td>Jaiswal, S., &amp; Ballal, M. S. (2017). Optimal load management of plug-in electric vehicles with demand side management in vehicle to grid application. 2017 IEEE Transportation Electrification Conference (ITEC-India). https:\/\/doi.org\/10.1109\/itec-india.2017.8356942<\/td>        <\/tr>\n            <tr data-row_id=\"62\" class=\"ninja_table_row_62 nt_row_id_62\">\n            <td>63<\/td><td>Jaiswal, G. C., Venikar, P. A., Ballal, M. S., Suryawanshi, H. M., &amp; Tutakne, D. R. (2017). Smart transformers for industrial applications. 2017 IEEE Transportation Electrification Conference (ITEC-India). https:\/\/doi.org\/10.1109\/itec-india.2017.8333713<\/td>        <\/tr>\n            <tr data-row_id=\"63\" class=\"ninja_table_row_63 nt_row_id_63\">\n            <td>64<\/td><td>Talapur, G. G., Suryawanshi, H. M., Shitole, A. B., Deshmukh, R. R., &amp; Ballal, M. S. (2017). Master-slave control based reliable micro-Grid with back-to-back voltage source converter as master DG. IECON 2017 &#8211; 43rd Annual Conference of the IEEE Industrial Electronics Society. https:\/\/doi.org\/10.1109\/iecon.2017.8216056<\/td>        <\/tr>\n            <tr data-row_id=\"64\" class=\"ninja_table_row_64 nt_row_id_64\">\n            <td>65<\/td><td>Jaiswal, G. C., Ballal, M. S., &amp; Tutakne. (2016). Health index based condition monitoring of distribution transformer. https:\/\/doi.org\/10.1109\/pedes.2016.7914222<\/td>        <\/tr>\n            <tr data-row_id=\"65\" class=\"ninja_table_row_65 nt_row_id_65\">\n            <td>66<\/td><td>Surya, G., Khan, Z. J., &amp; Ballal, M. S. (2016). A simplified cost effective condition monitoring and diagnostic system for detection of faults and protection of electrical machines. https:\/\/doi.org\/10.1109\/pedes.2016.7914413<\/td>        <\/tr>\n            <tr data-row_id=\"66\" class=\"ninja_table_row_66 nt_row_id_66\">\n            <td>67<\/td><td>Vilhekar, T. G., R, N. R., &amp; Ballal, M. S. (2016). Detection of winding faults in auxiliary and main windings of single phase squirrel cage induction motor by monitoring Lissajous patterns. https:\/\/doi.org\/10.1109\/pedes.2016.7914339<\/td>        <\/tr>\n            <tr data-row_id=\"67\" class=\"ninja_table_row_67 nt_row_id_67\">\n            <td>68<\/td><td>Jaiswal, G. C., Ballal, M. S., &amp; Tutakne. (2016b). Impact of power quality on the performance of distribution transformer. https:\/\/doi.org\/10.1109\/pedes.2016.7914344<\/td>        <\/tr>\n            <tr data-row_id=\"68\" class=\"ninja_table_row_68 nt_row_id_68\">\n            <td>69<\/td><td>Surya, G., Khan, Z. J., &amp; Ballal, M. S. (2016a). Classification of magnetic circuit asymmetry due to source supply unbalance, load variations and stator turn fault in induction motors using observer coil technique. https:\/\/doi.org\/10.1109\/tencon.2016.7848090<\/td>        <\/tr>\n            <tr data-row_id=\"69\" class=\"ninja_table_row_69 nt_row_id_69\">\n            <td>70<\/td><td>Vilhekar, T. G., Ballal, M. S., &amp; Umre, B. S. (2016). Application of Sweep Frequency Response Analysis for the detection of winding faults in induction motor. https:\/\/doi.org\/10.1109\/iecon.2016.7793565<\/td>        <\/tr>\n            <tr data-row_id=\"70\" class=\"ninja_table_row_70 nt_row_id_70\">\n            <td>71<\/td><td>Surya, G., Khan, Z., &amp; Ballal. (2016a). Radial flux signature analysis for identifying source unbalance and stator turn fault in cage motors using radial flux sensing coil. https:\/\/doi.org\/10.1109\/icpeices.2016.7853250<\/td>        <\/tr>\n            <tr data-row_id=\"71\" class=\"ninja_table_row_71 nt_row_id_71\">\n            <td>72<\/td><td>Wath, M., Raut, P., &amp; Ballal. (2016). Error compensation method for current transformer. https:\/\/doi.org\/10.1109\/icpeices.2016.7853244<\/td>        <\/tr>\n            <tr data-row_id=\"72\" class=\"ninja_table_row_72 nt_row_id_72\">\n            <td>73<\/td><td>Jaiswal, S., Wath, M., &amp; Ballal, M. S. (2016). Modeling the measurement error of energy meter using NARX model. https:\/\/doi.org\/10.1109\/i2mtc.2016.7520339<\/td>        <\/tr>\n            <tr data-row_id=\"73\" class=\"ninja_table_row_73 nt_row_id_73\">\n            <td>74<\/td><td>Kulkarni, A. R., Rajurkar, S. S., &amp; Ballal. (2016). Indian experience of utilisation of Synchrophasor system and its integration with Situational Awareness system. https:\/\/doi.org\/10.1109\/icpes.2016.7584176<\/td>        <\/tr>\n            <tr data-row_id=\"74\" class=\"ninja_table_row_74 nt_row_id_74\">\n            <td>75<\/td><td>Jaiswal, G. C., Tutakne, Ballal, M. S., &amp; PK, N. a. S. (2016). Oil level assessment of Distribution Transformer by development of Capacitance Model. https:\/\/doi.org\/10.1109\/icpes.2016.7584029<\/td>        <\/tr>\n            <tr data-row_id=\"75\" class=\"ninja_table_row_75 nt_row_id_75\">\n            <td>76<\/td><td>Vilhekar, T. G., Ballal, M. S., &amp; Suryawanshi, H. M. (2015). Application of double Park\u2019s vector approach for detection of inter-turn fault in induction motor. https:\/\/doi.org\/10.1109\/catcon.2015.7449529<\/td>        <\/tr>\n            <tr data-row_id=\"76\" class=\"ninja_table_row_76 nt_row_id_76\">\n            <td>77<\/td><td>Jaiswal, S., &amp; Ballal, M. S. (2015). Condition assessment of induction motor under different power quality events. https:\/\/doi.org\/10.1109\/catcon.2015.7449517<\/td>        <\/tr>\n            <tr data-row_id=\"77\" class=\"ninja_table_row_77 nt_row_id_77\">\n            <td>78<\/td><td>Surya, G. N., Khan, Z. J., &amp; Ballal, M. S. (2015). A novel radial flux sensing technique for stator turn fault detection in induction motors in online mode using observer coil. https:\/\/doi.org\/10.1109\/catcon.2015.7449515<\/td>        <\/tr>\n            <tr data-row_id=\"78\" class=\"ninja_table_row_78 nt_row_id_78\">\n            <td>79<\/td><td>Venikar, P. A., Ballal, M. S., Umre, B. S., &amp; Suryawanshi, H. M. (2015). Symmetrical components based advanced scheme for detection of incipient inter-turn fault in transformer. https:\/\/doi.org\/10.1109\/catcon.2015.7449521<\/td>        <\/tr>\n            <tr data-row_id=\"79\" class=\"ninja_table_row_79 nt_row_id_79\">\n            <td>80<\/td><td>Venikar, P. A., Ballal, M. S., Umre, B. S., &amp; Suryawanshi, H. M. (2015a). Transformer incipient inter-turn fault detection based on no-load current harmonic analysis. https:\/\/doi.org\/10.1109\/ptc.2015.7232294<\/td>        <\/tr>\n            <tr data-row_id=\"80\" class=\"ninja_table_row_80 nt_row_id_80\">\n            <td>81<\/td><td>Venikar, P. A., Ballal, M. S., Umre, B. S., &amp; Suryawanshi, H. M. (2014). Search coil based transformer inter-turn fault detection. https:\/\/doi.org\/10.1109\/npsc.2014.7103865<\/td>        <\/tr>\n            <tr data-row_id=\"81\" class=\"ninja_table_row_81 nt_row_id_81\">\n            <td>82<\/td><td>Nelson, A. A., Jaiswal, G. C., Ballal, M. S., &amp; Tutakne, D. R. (2014). Remote condition monitoring system for distribution transformer. https:\/\/doi.org\/10.1109\/npsc.2014.7103848<\/td>        <\/tr>\n            <tr data-row_id=\"82\" class=\"ninja_table_row_82 nt_row_id_82\">\n            <td>83<\/td><td>Nelson, A. A., Jaiswal, G. C., Makar, N., &amp; Ballal, S. (2014). Economical aspects of remote conditon monitoring system for distribution transformer. https:\/\/doi.org\/10.1109\/inpac.2014.6981133<\/td>        <\/tr>\n            <tr data-row_id=\"83\" class=\"ninja_table_row_83 nt_row_id_83\">\n            <td>84<\/td><td>Bhadane, K. V., Ballal, M. S., &amp; Moharil, R. M. (2014). Wavelet transform based power quality analysis of grid connected wind farm &#8211; An investigation of Power Quality Disturbances. https:\/\/doi.org\/10.1109\/icaee.2014.6838544<\/td>        <\/tr>\n            <tr data-row_id=\"84\" class=\"ninja_table_row_84 nt_row_id_84\">\n            <td>85<\/td><td>Venikar, P. A., Ballal, M. S., Umre, B. S., &amp; Suryawanshi, H. M. (2013). Condition assessment of transformer by park\u2019s vector and symmetrical components to detect inter turn fault. https:\/\/doi.org\/10.1109\/catcon.2013.6737491<\/td>        <\/tr>\n            <tr data-row_id=\"85\" class=\"ninja_table_row_85 nt_row_id_85\">\n            <td>86<\/td><td>Ballal, M. S., Ballal, D. M., Suryawanshi, H. M., &amp; Choudhari, B. N. (2013). Computational intelligence algorithm based condition monitoring system for power transformer. https:\/\/doi.org\/10.1109\/catcon.2013.6737538<\/td>        <\/tr>\n            <tr data-row_id=\"86\" class=\"ninja_table_row_86 nt_row_id_86\">\n            <td>87<\/td><td>K. V. Bhadane, M. S. Ballal and R. M. Moharil, &#8220;Investigation for Causes of Poor Power Quality in Grid Connected Wind Energy &#8211; A Review,&#8221; 2012 Asia-Pacific Power and Energy Engineering Conference, Shanghai, China, 2012, pp. 1-6, doi: 10.1109\/APPEEC.2012.6307152.<\/td>        <\/tr>\n            <tr data-row_id=\"87\" class=\"ninja_table_row_87 nt_row_id_87\">\n            <td>88<\/td><td>Ballal, M. S., Khan, Z. J., Suryawanshi, H. M., &amp; Mishra, M. K. (2006). Detection of Inter-turn Short-circuit Fault in Induction Motor Using Theory of Instantaneous Symmetrical Components. https:\/\/doi.org\/10.1109\/icit.2006.372214<\/td>        <\/tr>\n            <tr data-row_id=\"88\" class=\"ninja_table_row_88 nt_row_id_88\">\n            <td>89<\/td><td>Ballal, Khan, Z., Mishra, M., &amp; Sonolikar, R. (2005). Fuzzy system for the detection of winding insulation condition and bearing wear in induction motor. https:\/\/doi.org\/10.1109\/indico.2004.1497823<\/td>        <\/tr>\n    <\/tbody><!--ninja_tobody_rendering_done-->\n    <\/table>\n    \n    \n    \n<\/div>\n                    <\/div>\n\t\t                    <\/div>\n        <\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Dr. M. S. Ballal Brief Bio Education Contact Details Research Interest Linkedin Sponsored Research Projects Consultancy Projects Book or Book Chapters Patents STTP &#038; Workshop Administrative Responsibilities Awards &#038; Honors Journal Publications Conference Publications Sr. No. Title of Project Period Sponsoring Organisation Amount (in lakhs) No. of Investigator(s) PI\/CoPI 1 A Solution for Stable and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-552","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/vnit.ac.in\/engineering\/electrical\/wp-json\/wp\/v2\/pages\/552","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vnit.ac.in\/engineering\/electrical\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vnit.ac.in\/engineering\/electrical\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vnit.ac.in\/engineering\/electrical\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vnit.ac.in\/engineering\/electrical\/wp-json\/wp\/v2\/comments?post=552"}],"version-history":[{"count":31,"href":"https:\/\/vnit.ac.in\/engineering\/electrical\/wp-json\/wp\/v2\/pages\/552\/revisions"}],"predecessor-version":[{"id":1954,"href":"https:\/\/vnit.ac.in\/engineering\/electrical\/wp-json\/wp\/v2\/pages\/552\/revisions\/1954"}],"wp:attachment":[{"href":"https:\/\/vnit.ac.in\/engineering\/electrical\/wp-json\/wp\/v2\/media?parent=552"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}